Williams Sound WIR SYS 2 specifications Multiple Emitters Installed to Maximize Coverage, TX9TX9

Page 6

SoundPlus® Value Courtroom System • Model WIR SYS 2

SoundPlus® Value Courtroom System • Model WIR SYS 2

D

Multiple Emitters Installed to Maximize Coverage

Fig. 8a: Overlapping Illumination Patterns to Cover Larger Listening Areas

TX9TX9

TX9TX9

Fig. 8a above is a typical example of how multiple emitters are used to cover larger listening areas. Generally it is desirable for the illumination patterns to overlap. Note: The coverage area will vary depend- ing on the infrared receiver being used; refer to Figures 4 and 7 to determine how many emitters are required to achieve full coverage of a listening area.

Fig. 8b: Overlapping Illumination Patterns to Cover Larger Listening Areas

 

Coverage Area

TX9

with Single Emitter

 

TX9

Coverage Area

with Second Emitter

 

 

Added to Same

 

Emission Point

 

(50% increase)

When two emitters are used at the same emission point in single channel mode, the overall coverage area incre- ses 50%. When using an RX22-4 receiver, as a result, the coverage area will increase to an estimated 42,000 ft2 (3,902 m2); the RX14-2 will increase to 5,250 ft2 (488 m2); the RX16 will increase to 4,590 ft2 (426 m2 ).

NOTE: SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE!

 

©2006, Williams Sound Corp. MCAT 028D

6

 

 

 

Image 6
Contents Description MOD 232 ModulatorTFP 016, UL/CSA WIR TX9 Emitter TFP 010, UL/CSACourtroom SoundPlus Value Courtroom System Maximum Range When Using the RX22-4 Infrared Receiver Horizontal and Vertical Radiation Polar PlotsMultiple Emitters Installed to Maximize Coverage TX9TX9SoundPlus Value Courtroom System Model WIR SYS WIR RX22-4 ReceiverWIR RX14-2 Receiver WIR RX14-2 Side ViewTwo-Channel System Diagram Two-Channel SystemBid Specs Modulator, Model MODFour-Channel Receiver, Model RX22-4 Contact United States