6.0Troubleshooting
PROBLEM | PROBABLE CAUSE | SOLUTION |
| B roken B elts (if A pplicable) | R eplace B elts |
| Im proper B elt T ension (if |
|
| A pplicable) | A djust B elt T ension |
N o P ressure | C logged Inlet W ater F ilter | C lean or R eplace W ater Inlet F ilter |
| C logged N ozzle | C lean D ebris from N ozzle |
|
|
|
| W orn or Incorrect N ozzle | R eplace N ozzle w ith C orrect S ize |
| Im proper B elt T ension (if |
|
Low P ressure | A pplicable | A djust B elt T ension |
Im proper E ngine R .P .M . | C onsult S ervice C enter | |
|
| C heck W ater S upply and C lean |
| Inadequate W ater S upply | Inlet F ilter |
|
|
|
|
| C heck W ater S upply and Inlet |
| Inadequate W ater S upply | W ater F ilter |
P ulsation or H oses V ibrating | P artially C logged N ozzle | C lean or R eplace N ozzle |
D ebris in P um p V alves | C onsult S ervice C enter | |
| Incorrect N ozzle S ize | Install C orrect S ize N ozzle |
|
|
|
W ater Leaking U nder P um p | W orn P lunger S eals | C onsult S ervice C enter |
W orn or D am aged P lungers | C onsult S ervice C enter | |
| P um p R unning D ry | C heck W ater S upply |
|
|
|
W ater in P um p O il | W orn P um p S eals | C onsult S ervice C enter |
W orn or D am aged P lungers | C onsult S ervice C enter | |
| C ondensation in P um p C rankcase | C hange O il |
|
|
|
| O il Level T oo H igh | D rain O il and F ill to P roper level |
|
| D rain O il and F ill w ith C orrect O il |
P um p O il Leak | W rong O il T ype | S im pson 30 W T N on |
O perating on U nlevel S urface | M ove T o Level S urface | |
| T ire P ressure T oo Low or F lat | Inflate T ire or R epair Leak |
|
|
|
R ecoil S tarter H ard to P ull | P ressure B uilt up in S ystem | P ull T rigger w hile S tarting U nit |
|
|
|
E ngine D ies W hen T rigger is | U nloader V alve is B roken or |
|
R eleased | M isadjusted | C onsult S ervice C enter |
|
|
|
www.simpsoncleaning.com | page 11 |