North Star 10000 PPG Installation, Load Application, Starting Electric Motors, 120V, 60 Hz Motors

Page 7

INSTALLATION

OUTDOORS: Choose a location where the generator will not be exposed to rain, snow or direct sunlight. Position the generator on secure, level ground so it will not tip or slide down a hill. Place the generator so that the exhaust fumes will not be directed towards people.

The installation site must be free from water, moisture, or dust. All electrical components should be protected from excessive moisture or the insulation system will deteriorate and result in grounding or shorting out the generating system.

Foreign matters, such as dust, dirt, sand, lint, or abrasive materials can cause damage to the generator head and engine if allowed into its cooling system.

NEVER install your generator inside confined areas. Inside installation can cause health hazards or death.

DANGER Remember, exhaust fumes are deadly carbon monoxide gas, and must be vented to the outside where there are no people. Cooling air of sufficient amounts must be allowed to flow in and exhausted out to ensure proper cooling of the engine and generator head.

LOAD APPLICATION

It is important to determine the total electrical load before it is connected to the generator. The two major factors in determining the life of a generator head are: heat build up, caused by overloading the generator; and corrosive contaminants that attack the wiring insulation. If the generator is overloaded, the wires become excessively hot and cause the insulation to break down, reducing its ability to resist corrosive contaminants. Over time the effectiveness of the insulation is eliminated and a dead short can result.

Always compare the generator nameplate data with that of the equipment to be used to ensure that watts, volts, amperage, and frequency requirements are suitable for operating equipment. The wattage listed on the equipment nameplate is its rated output. However, some equipment may require three to ten times more wattage than its rating on the nameplate, as the wattage is influenced by the equipment efficiency, power factor and starting system. NOTE: If wattage is not given on equipment nameplate, approximate wattage may be determined by multiplying nameplate voltage by nameplate amperage.

VOLTS

X AMPS

= WATTS

Example: 120V

X 5A

= 600W

When connecting

a resistive load such as

incandescent lights, heaters or common electric power

tools, a capacity of up to the generator full rated wattage output can be used.

When connecting a resistive-inductive load such as a fluorescent or mercury light, transformers or inductive coils, a capacity of up to 0.6 times the generator’s full rated output can be used.

Always allow the generator to reach operating speed before a load is applied.

STARTING ELECTRIC MOTORS

Electric motors require much more current (amps) to start than to run. Some motors, particularly low cost split-phase motors, are very hard to start and require 5 to 7 times more current to start than to run. Capacitor motors are easier to start and usually require 2 to 4 times as much current to start as to run. Repulsion Induction motors are the easiest to start and require

1.5to 2.5 times as much to start as to run.

Most fractional motors take about the same

amount of current to run them whether they are of Repulsion-Induction (RI), Capacitor (Cap), or Split- Phase (SP) type. The following chart shows the approximate current required to start and run various types and sizes of 120 volt 60 cycle electric motors under various conditions.

120V, 60 Hz Motors

 

Starting Amps

 

Hp motor

Running

RI type

 

Cap type

 

SP type

 

Watts

 

 

 

 

 

1/6

525

7-11

 

9-18

 

16-22

1/4

700

9-15

 

12-23

 

22-32

 

 

 

 

 

 

 

1/3

875

11-18

 

14-29

 

26-35

1/2

1175

15-25

 

20-40

 

NA

1

1925

24-40

 

32-64

 

NA

1 1/2

2400

30-50

 

40-80

 

NA

2

2900

36-60

 

48-96

 

NA

3

4075

51-85

 

68-136

 

NA

 

 

 

 

 

 

 

5

6750

84-140

 

112-224

 

NA

The figures given above are for an average load such as a blower or fan. If the electric motor is connected to a hard starting load, such as an air compressor, it will require more starting current. If it is connected to a light load, such as a power saw, it will require less starting current. The exact requirement will also vary with the brand or design of the motor.

Generators respond to severe overloading differently than the power line. When overloaded, the engine is not able to supply enough power to bring the electric motor up to operating speed. The generator responds to the high initial starting current, but the engine speed drops sharply. The overload may stall the engine. If allowed to operate at very low speeds, the electric motor starting winding will burn out in a short time. The generator head winding might also be damaged.

6

Image 7
Contents O v e n P e r f o r m a n c e Thank YOU Table of ContentsSpecifications Description Machine Component IdentificationReference 1 Air Cleaner. Refer to your Honda Generator FeaturesReference 7 120V Receptacle. The generator Introduction Ansi Safety Definitions Rules for Safe OperationsStarting Electric Motors InstallationExample = 600W When connecting Resistive load such as Load ApplicationLoad Requirements PRE-START PreparationsExtension Cords Current/Pow er Maximum Extension Cord LengthEngine Care Starting ManualStarting Electric StoppingGenerator Care Problem Possible Causes Possible Remedies Troubleshooting

10000 PPG specifications

The North Star 10000 PPG is a cutting-edge power generation unit designed for both commercial and industrial applications. Built with the latest technologies in the realm of portable power generation, the North Star 10000 PPG stands out for its efficiency, durability, and ease of use.

One of the main features of the North Star 10000 PPG is its robust engine. The unit is equipped with a powerful four-stroke engine that delivers an impressive output of 10,000 watts, making it suitable for various applications, from powering tools at a construction site to providing backup power for homes and businesses during outages. The engine has been engineered for optimal fuel efficiency, ensuring that users get the most out of every gallon of fuel consumed.

Another key characteristic is its advanced inverter technology. The North Star 10000 PPG uses a high-performance inverter system that produces clean, stable power suitable for sensitive electronics. This feature is especially beneficial for users who need to power devices such as computers, medical equipment, or any appliance that requires stable electrical input.

The design of the unit also incorporates a steel frame that provides enhanced protection against rugged conditions. Its rain-resistant feature means it can operate efficiently even in adverse weather, making it ideal for outdoor usage. The compact and portable nature of the unit allows for easy transport, with built-in wheels and a sturdy handle making it user-friendly for individuals on the go.

Safety is paramount in the design of the North Star 10000 PPG. The unit comes equipped with multiple safety features, including low-oil shut-off, overload protection, and noise reduction technology. This focus on safety ensures a reliable operation while minimizing the risk of accidents or failures during use.

Moreover, the North Star 10000 PPG has a user-friendly control panel that simplifies operation. With integrated display gauges showing power output and fuel levels, users can quickly assess the unit's performance at a glance. The model also boasts a long run time, providing extended operation without the need for frequent refueling.

Overall, the North Star 10000 PPG represents a significant advancement in portable power generation technology. Its combination of power, efficiency, safety features, and user-friendly design makes it a top choice for anyone in need of reliable power solutions, whether for emergency backup or routine use in various applications. As a versatile and powerful generator, it meets the needs of a diverse range of users.