North Star M1573001A owner manual Grounding Instructions, Extension Cords

Page 5

Grounding Instructions

This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electrical shock. This product is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

DANGER - Improper connection of the equipment - grounding conductor can result in a risk of electrocution. Check with a qualified electrician or service personnel if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the product - if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Do not use any type adapter with this product.

1. For a product rated 125 volts or less:

GROUND FAULT CIRCUIT INTERRUPTER PROTECTION

This pressure washer is provided with a ground fault circuit interrupter (GFCI) built into the plug of the power supply cord. This device provides additional protection from the risk of electric shock. Should replacement of the plug or cord become necessary, use only identical replacement parts that include GFCI protection.

2. For a product rated more than 125 volts:

GROUND FAULT CIRCUIT INTERRUPTER PROTECTION

To comply with the National Electric Code (NFPA 70) and to provide additional protection from the risk of electric shock, this pressure washer should only be connected to a receptacle that is protected by a ground fault circuit interrupter (GFCI).

Extension Cords

Use only 3-wire extension cords that have 3 prong grounding-type plugs and 3-pole cord connectors that accept the plug from the product. Use only extension cords that are intended for outdoor use. These extension cords are identified by a marking “Acceptable for use with outdoor appliances; store indoors while not in use.” Use only extension cords having an electrical rating not less than the rating of the product. Do not abuse extension cord and do not yank on any cord to disconnect. Keep cord away from heat and sharp edges. Always disconnect the extension cord from the receptacle before disconnecting the product from the extension cord.

Warning - To reduce the risk of electrocution, keep all connections dry and off the ground. do not touch plug with wet hands.

SAVE THESE INSTRUCTIONS

5

Image 5 Contents
Item Numbers 1573001,1573011 M1573001AHazard Signal Word Definitions Table of Contents Important Safety Instructions Extension Cords Grounding InstructionsCall 1-800-270-0810 to order new labels Motor/Pump/Base Assembly Handle Assembly InstructionsUnpack Lance Spray Gun Hardware BagVented fill cap Flange Nut Qty Hook Detail III. Handle AssemblyNozzles Machine Component IdentificationOperation Instructions Pump Component IdentificationWater Supply Model Time to fill 5 gallon bucketSkin puncture hazard Attaching the Lance Spray Gun Safety LockAttach Quick Connect Couplers Installing NozzlesApplying Chemicals Risk of exposure to dangerous chemicalsMaintenance Schedule What to Check When To Check What to Do Maintenance and StorageMaintenance Mode Oil capacity 4.3oz. .13L Oil capacity 8.5 oz. .25L Pump Oil ChangeComet BXD 1617E Pump Cat 3DNX25GSI Pump Cat 2DX15ES Pump Winter Storage Cause Solution Troubleshooting ProblemWiring Diagram Specifications1573001 1573021Wiring Diagram Part Explosion M1573001 Rev a Models Item # Description QTY