North Star 157394 manual Stopping the Pressure Washer, Using the Detergent Injector

Page 9

STOPPING THE PRESSURE WASHER

!To protect your safety and the service of your RANGER 157394, you must follow the procedure for stopping the pressure washer outlined

below:

1.Run one gallon of clean water through the used detergent lines. (If detergent has been used during this operation run).

2.Turn burner switch to “OFF” (0 position).

3.Squeeze the trigger and discharge cool water for 3 minutes to cool the burner component.

4.Turn the unit “OFF” with the main switch on the control panel.

5.Turn off the water supply immediately.

6.Squeeze the trigger gun to relieve system pressure and drain excess water.

7.Disconnect power cord and unit hoses.

USING THE DETERGENT INJECTOR

This feature is designed for use with mild detergents. North Star detergents are highly recommended for use with all North Star pressure washers.

1.Prepare cleaning solution according to the detergent label directions.

2.Immerse the strainer end of the clear vinyl hose into the detergent solution to allow detergent to siphon. Turn the nozzle at the end of the wand to the left for low pressure.

3.Start the unit as directed in the OPERATING INSTRUCTIONS. Brace yourself and the triggered gun. The detergent and water mixture will exit the low pressure nozzle.

4.Apply the solution by spraying from low surface and move up; use long, overlapping strokes. Applying from the bottom, up helps avoid streaking. Do not allow the detergent solution to dry on any surface.

5.Turn nozzle at the end of the wand to the right for the high pressure rinse mode. It takes 30 seconds to purge all detergent from the system lines.

6.Start at the top and work down for the best rinsing results.

7.Rinse the detergent injector system by running 1 gallon of clean water through after each use. This prevents corrosion or detergent residue that causes mechanical problems during later uses of your RANGER 157394.

- 10 -

Image 9
Contents HOT / Cold Water Pressure Washer Ranger North Star Ranger Table of ContentsElectrical Safety Safety InstructionsGeneral Safety Detergent SafetyUnpacking Electrical Requirements GROUND-FAULT-CIRCUIT-INTERRUPTERGrounding Instructions Extension CordsPRE-OPERATION Check Installation InstructionsClothing PumpOperating Instructions Starting the Pressure WasherCold Water Operation HOT Water Operation Stopping the Pressure Washer Using the Detergent InjectorMaintenance Symptoms Causes Remedies TroubleshootingCode Description Qty Model FRAME, Cowling Assembly Exploded ViewPump & Motor CO90270079 Cost more than whole unit PUMP, Motor Assembly Exploded View5025 Unloader Valve Exploded View Electric System Exploded View BURNER, Boiler Exploded View GUN, HOSE, Wand Assembly Exploded View