Kyocera KD255GX-LFB2, KD250GX-LFB2 manual Standard Test Conditions STC, System Design

Page 2

 

 

 

 

 

 

 

KD200-60 F Series

ELECTRICAL SPECIFICATIONS

 

 

MODULE CHARACTERISTICS

Standard Test Conditions (STC)

 

 

Dimensions:Cells per module:

605.43in/38(6 x 10).98in/1.81in

2

 

o

C module temperature, AM 1.5 spectrum*

 

length/width/height

(1662mm/990mm/46mm)

STC = 1000 W/M irradiance, 25

 

 

Dimensions:

65.43in/38.98in/1.81in

 

KD250GX-LFB23

KD255GX-LFB23

 

length/width/height

(1662mm/990mm/46mm)

 

 

Weight:

44.1lbs (20.0kg)

 

250

 

 

255

W

Weight:

44.1lbs (20.0kg)

Pmax

 

 

 

 

Vmp

29.8

 

 

30.4

V

PACKAGING SPECIFICATIONS

 

 

 

 

 

 

Imp

8.39

 

 

8.39

A

Modules per pallet:

20

Voc

36.9

 

 

37.6

V

Pallets per 53’ container:

36

Isc

9.09

 

 

9.09

A

Pallet box dimensions:

66in/40in/47in

 

 

length/width/height

(1675mm/1005mm/1175mm)

Ptolerance

+5/-0

 

+5/-0

%

Pallet box weight:

990 lbs (450kg)

Nominal Operating Cell Temperature Conditions (NOCT)

 

 

 

NOCT = 800 W/M2 irradiance, 20oC ambient temperature, AM 1.5 spectrum*

 

 

 

T

45

 

 

45

oC

 

 

NOCT

 

 

 

 

 

 

 

Pmax

180

 

 

184

W

 

 

Vmp

26.8

 

 

27.4

V

 

 

Imp

6.72

 

 

6.72

A

 

 

Voc

33.7

 

 

34.4

V

 

 

Isc

7.36

 

 

7.36

A

 

 

PTC

223.7

 

228.3

W

 

 

Temperature Coefficients

 

 

 

 

 

 

P

-0.46

 

-0.46

%/oC

 

 

max

 

 

 

 

 

 

 

V

-0.52

 

-0.52

%/oC

 

 

mp

 

 

 

 

 

 

 

I

0.0065

0.0065

%/oC

 

 

mp

 

 

 

 

 

 

 

V

-0.36

 

-0.36

%/oC

 

 

oc

 

 

 

 

 

 

 

I

0.060

 

0.060

%/oC

 

 

sc

 

 

 

 

 

 

 

Operating

-40 to +90

-40 to +90

oC

 

 

Temp

 

 

 

 

 

 

 

System Design

 

 

 

 

 

 

 

Series Fuse Rating

 

 

 

 

15 A

 

 

Maximum DC System Voltage (UL)

 

600 V

 

 

Hailstone Impact

 

 

 

in (25mm) @ 51mph (23m/s)

 

 

*Subject to simulator measurement uncertainty of +/- 3%.

KYOCERA reserves the right to modify these specifications without notice.

NEC 2008 COMPLIANT UL 1703 LISTED

WARNING: Read the instruction manual in its entirety prior to handling, installing & operat- ing Kyocera Solar modules.

032114

 

OUR VALUED PARTNER

 

 

 

KYOCERA Solar, Inc. 800-223-9580 800-523-2329 fax

www.kyocerasolar.com

 

 

 

 

Image 2
Contents Certifications Cutting Edge TechnologyQuality Built System Design Nominal Operating Cell Temperature Conditions NoctStandard Test Conditions STC