Homelite HG6000 manual Starting the Engine, Stopping the Engine

Page 16

OPERATION

If using an oxygenated fuel, make sure it is unleaded and meets the minimum octane rating requirements. Before using an oxygenated fuel, try to confirm the fuel’s contents. Some states/provinces require this information to be posted on the pump. The following are the EPA approved percentages of oxygenates:

Ethanol (ethyl or grain alcohol) 10% by volume. You may use gasoline containing up to 10% ethanol by volume. Gasoline containing ethanol may be marketed under the name “Gasohol.”

MTBE (methyl tertiary butyl ether) 15% by volume. You may use gasoline containing up to 15% MTBE by volume.

Methanol (methyl or wood alcohol) 5% by volume. You may use gasoline containing up to 5% methanol by volume as long as it also contains cosolvents and corrosion inhibi- tors to protect the fuel system. Gasoline containing more than 5% methanol by volume may cause starting and/or performance problems. It may also damage metal, rubber, and plastic parts of the generator or your fuel system.

RECOIL

STARTER ENGINE

GRIP SWITCH

FUEL

AC CIRCUIT

BREAKER

CIRCUIT

BREAKER

Fig. 8

If you notice any undesirable operating symptoms, try another service station or switch to another brand of gasoline.

NOTE: Fuel system damage or performance problems re- sulting from the use of an oxygenated fuel containing more than the percentages of oxygenates stated previously are not covered under warranty.

CAUTION:

On a level surface with the engine off, check the oil level before each use of the generator.

FUEL

VALVE

Fig. 9

PULL CHOKE

LEVER OUT

TO START

STARTING THE ENGINE

 

See Figures 8 - 10.

 

NOTE: If location of generator is not level, the unit may not

 

start or may shut down during operation.

 

Unplug all loads from the generator.

 

Switch the AC circuit breakers to the OFF ( O ) position.

 

Turn the fuel valve to the ON position.

PUSH CHOKE

Pull the choke lever to the START position.

LEVER IN TO RUN

 

NOTE: If engine is warm or the temperature is above

Fig. 10

50˚F, push the choke lever in to the RUN position.

Put the engine switch in the ON ( I ) position.

STOPPING THE ENGINE

Pull the recoil starting grip until the engine runs (a maxi-

mum of 6 times).

See Figures 8 - 9.

NOTE: Do not allow the grip to snap back after starting;

To stop the engine under normal operating conditions:

return it gently to its original place.

Remove any load from the generator.

Allow the engine to run for 30 seconds, then push the

Place the voltage selector in the center (OFF) position.

choke lever in to the RUN position.

Switch the AC circuit breakers to the OFF position.

Switch the AC circuit breakers to the ON position.

Turn the fuel valve to the OFF position.

 

Put the engine switch in the OFF ( O ) position.

To stop the engine in an emergency situation: Put the engine switch in the OFF ( O ) position.

Page 16

Image 16
Contents OPERATOR’S Manual Save this Manual for Future ReferenceTable of Contents IntroductionGeneral Safety Rules Specific Safety Rules Symbols Name DESIGNATION/EXPLANATIONService Symbol Signal MeaningSafety Labels Ground Fault Circuit Interrupter Reset ButtonElectrical Extension Cord Cable SizeGenerator Capacity Power ManagementExample Features Product SpecificationsEngine Switch Know Your GeneratorAC Circuit Breaker AIR FilterKey Loose Parts ListQty Assembly Installing the WheelsInstalling the Frame Supports UnpackingInstalling the Handles OperationApplications Cotter PIN Clevis PIN Generator Frame HandleUsing Fuel Stabilizer Before Operating the UnitCHECKING/ADDING OIL CHECKING/ADDING FuelStarting the Engine Stopping the EngineMaintenance General MaintenanceCHECKING/CLEANING AIR Filter To clean the unitSpark Plug Maintenance Cleaning Fuel Sediment CUPSediment CUP Spark Plug CAP Cleaning the Exhaust Port and Muffler Spark ArrestorDraining Fuel TANK/CARBURETOR TransportingMaintenance Schedule StorageStorage Time Prior to Storing Before After 1st month Every 3 months Every 6 monthsTroubleshooting Problem Possible Cause SolutionWiring Diagram Generator symbolic circuitWarranty Limited Warranty StatementService California Proposition

HG6000 specifications

The Homelite HG6000 is a versatile and robust portable generator designed to provide reliable power for various applications. Whether for home backup during an outage, powering tools on a job site, or providing electricity for recreational activities, the HG6000 stands out in its class with a blend of performance, convenience, and durability.

One of the main features of the Homelite HG6000 is its impressive power output. This generator delivers a surge wattage of 6000 watts and a running wattage of 5500 watts, making it capable of handling major appliances such as refrigerators, air conditioners, and power tools with ease. The generator's 7.5 HP engine ensures that it can sustain consistent power delivery, making it ideal for both emergency and long-term usage.

In terms of fuel efficiency, the Homelite HG6000 operates on gasoline and features a 4-gallon fuel tank. This allows for extended operation times, providing run times of up to 8 hours at a 50% load. The generator's carbureted engine is designed for low emissions while still maintaining optimal performance, meeting the stringent EPA regulations, which is an added advantage for environmentally conscious users.

Portability is another significant characteristic of the Homelite HG6000. It is equipped with a rugged frame and has solid wheels, allowing for easy transportation across various terrains. Weighing approximately 130 pounds, it strikes a balance between portability and stability, ensuring that it remains stable during operation.

The generator includes several convenience features that enhance usability. It comes with multiple outlets, including two 120V 20A household outlets and a 120V 30A locking outlet, allowing users to connect multiple devices simultaneously. The integrated circuit breaker provides extra protection, ensuring the safety of connected devices.

Moreover, the HG6000 is designed with ease of maintenance in mind. It features an easily accessible oil fill and drain, as well as a removable air filter, simplifying the maintenance process for users.

In conclusion, the Homelite HG6000 is a powerful and reliable generator tailored to meet the diverse needs of homeowners and professionals alike. With its strong performance capabilities, fuel efficiency, user-friendly features, and portability, it serves as an excellent solution for those seeking dependable power in various situations.