Global Machinery Company GEN instruction manual Troubleshooting, No electrical output, Tripping

Page 15

Troubleshooting

Trouble

Possible cause

Suggested remedy

 

 

 

 

Engine will not start

1. Low on fuel/oil content

1.

Add fuel/oil mix

 

 

 

 

 

 

2.

Ignition switch in “Off” position

2.

Turn to “ON” position

 

 

 

 

 

 

3.

Faulty spark plug

3.

Replace spark plug

 

 

 

 

 

 

4.

Choke in wrong position

4.

Adjust choke accordingly

 

 

 

 

 

5. Fuel shut-off valve in closed position

5.

Open fuel shut-off valve

 

 

 

 

 

 

6.

Unit loaded during start-up

6.

Remove load from unit

 

 

 

 

 

 

7.

Spark plug wire loose

7.

Attach wire to spark plug

 

 

 

 

No electrical output

1. Faulty receptacle

1.

Have service centre replace receptacle

 

 

 

 

 

 

2.

Circuit breaker kicked out

2.

Depress and reset

 

 

 

 

 

3.

Defective capacitor

3. Have service centre replace capacitor

 

 

 

 

 

 

4.

Faulty power cord

4.

Replace cord

 

 

 

 

Repeated circuit breaker

1. Overload

1.

Reduce load.

tripping

 

 

 

 

2.

Faulty cords or equipment.

2. Check for damaged, bare, or frayed

 

 

 

 

wires on equipment. Replace.

 

 

 

 

Generator overheating

1. Generator overloaded.

1.

Reduce load

 

 

 

 

 

 

2.

Insufficient ventilation.

2.

Move to adequate supply of fresh air.

 

 

 

 

 

15

Image 15
Contents 850W Generator Contents Introduction Description of symbolsSpecifications Dear CustomerGeneral safety instructions for power tools Hazard What could happen How to prevent it For generator Speed settingsRisk of fire Inadequate ventilationManner Risk of breathing inhalation hazardRisk of unsafe operation SurfacesRisk of hot surfaces Risk of moving partsRisk from lifting Unpacking Additional safety rules for generatorsKnow your product Earthing the generator Fitting the handleMixing the fuel Filling the fuel tankStopping the engine Connecting apparatus to the generatorTurn the engine switch to the ‘stop’ position Let the overload cut out switch cool downSpark plugs Periodic maintenanceGenerator maintenance StorageStop the engine CleaningPetrol tank filter RepairsGenerator overheating TroubleshootingNo electrical output TrippingSave this Manual for future reference