Troubleshooting
Trouble | Possible cause | Suggested remedy | |||
|
|
|
| ||
Engine will not start | 1. Low on fuel/oil content | 1. | Add fuel/oil mix | ||
|
|
|
|
| |
| 2. | Ignition switch in “Off” position | 2. | Turn to “ON” position | |
|
|
|
|
| |
| 3. | Faulty spark plug | 3. | Replace spark plug | |
|
|
|
|
| |
| 4. | Choke in wrong position | 4. | Adjust choke accordingly | |
|
|
|
| ||
| 5. Fuel | 5. | Open fuel | ||
|
|
|
|
| |
| 6. | Unit loaded during | 6. | Remove load from unit | |
|
|
|
|
| |
| 7. | Spark plug wire loose | 7. | Attach wire to spark plug | |
|
|
|
| ||
No electrical output | 1. Faulty receptacle | 1. | Have service centre replace receptacle | ||
|
|
|
|
| |
| 2. | Circuit breaker kicked out | 2. | Depress and reset | |
|
|
|
| ||
| 3. | Defective capacitor | 3. Have service centre replace capacitor | ||
|
|
|
|
| |
| 4. | Faulty power cord | 4. | Replace cord | |
|
|
|
| ||
Repeated circuit breaker | 1. Overload | 1. | Reduce load. | ||
tripping |
|
|
|
| |
2. | Faulty cords or equipment. | 2. Check for damaged, bare, or frayed | |||
| |||||
|
|
| wires on equipment. Replace. | ||
|
|
|
| ||
Generator overheating | 1. Generator overloaded. | 1. | Reduce load | ||
|
|
|
|
| |
| 2. | Insufficient ventilation. | 2. | Move to adequate supply of fresh air. | |
|
|
|
|
|
15