Troubleshooting

Trouble

Possible cause

Suggested remedy

 

 

 

Engine will not start

1. Low on fuel or oil content

1. Add fuel or oil

 

 

 

 

 

 

2.

Ignition switch in “Off” position

2.

Turn the ignition to the ‘START’ position

 

 

 

 

if using key start, or ‘ON’ position if

 

 

 

 

manually starting.

 

 

 

 

 

 

3.

Faulty spark plug

3.

Replace spark plug

 

 

 

 

 

4.

Choke in wrong position

4. Adjust choke accordingly

 

 

 

 

 

 

5.

Fuel shut-off valve in closed position

5.

Open fuel shut-off valve

 

 

 

 

 

 

6.

Unit loaded during start-up

6.

Remove load from unit

 

 

 

 

 

7.

Spark plug wire loose

7. Attach wire to spark plug

 

 

 

 

 

 

8.

Fuel filter (tap extension filter) blocked

8.

Check by removing fuel line from

 

 

 

 

carburetor and opening tap. If no flow,

 

 

 

 

and tap is on, and fuel in tank there is

 

 

 

 

a blockage.

 

 

 

 

Remove tap and clean filter.

 

 

 

 

No electrical output

1. Faulty receptacle

1.

Have service centre replace receptacle

 

 

 

 

 

 

2.

Circuit breaker kicked out

2.

Depress and reset

 

 

 

 

 

 

3.

Worn Brushes

3.

Have service centre replace brushes

 

 

 

 

 

 

4.

Faulty power cord

4.

Replace cord

 

 

 

 

Repeated circuit breaker

1. Overload

1.

Reduce load

tripping

 

 

 

 

2.

Faulty cords or equipment

2. Check for damaged, bare, or frayed

 

 

 

 

 

wires on equipment. Replace.

 

 

 

 

 

3.

D.C Tripping

3. Remove or reduce any 240V appliances

 

 

 

 

Generator overheating

1. Generator overloaded

1.

Reduce load

 

2.

Insufficient ventilation

2.

Move to adequate supply of fresh air

 

 

 

 

 

18

Image 18
Contents AVR Generator Contents Introduction Description of symbolsSpecifications Environmental protectionGeneral safety instructions for power tools Risk of electrocution and fire Risk of fire To Vehicle Surfaces Risk of breathing inhalation hazardRisk of unsafe operation Carbon monoxide exhaust fumesRisk of hot surfaces Risk of moving partsRisk from lifting Additional safety rules for generators UnpackingKnow your product Checking the engine oil Automatic voltage regulator AVRPreparing the generator Checking the engine fuelConnecting apparatus to the generator Starting the engineStopping the engine Charging the battery 20CPeriodic maintenance AC and DC overload cut out Generator maintenanceEngine oil replacement StorageAir filter Tap extension fuel filterCleaning Petrol tank filterRepairs Repeated circuit breaker TroubleshootingNo electrical output TrippingPage GMC customer assist