Mounting Instructions for Model 6370C Parallel Power Kit
For Honda E3000i Generators Only
5 | 6 |
| CIRCUIT BREAKER |
|
|
|
|
| STEP 6 | |
|
|
|
|
| Insert the set of longer Parallel Cables into “Parallel Operation” jacks | |
|
|
|
|
| on second generator. Attach green/yellow ground cable to grounding | |
|
| GROUND |
|
| stud on the lower right side of the second generator as well. | |
|
|
|
| |||
|
|
|
|
| During operation, if the Parallel Power Kit is not feeding power to | |
|
|
|
|
| ||
STEP 5 | ||||||
your load when generators are running, it is possible that the circuit | ||||||
Insert short Parallel Cables into “Parallel Operation” | breaker has been tripped. You will need to reset circuit breaker on | |||||
jacks on the first generator. Do not be concerned with | the front of the Parallel Power Kit to “ON”. | |||||
polarity when connecting to these outlets, as the |
| |||||
polarity is handled by the internal computer chip within | Be sure to shut down generators before connecting to or | |||||
the EU3000i. Then attach the first green/yellow ground | disconnecting from Parallel Power Kit. | |||||
cable to grounding stud on the lower right side of the |
| |||||
first generator using a screwdriver. | For 120 volt applications ONLY. | |||||
|
|
|
|
|
| |
|
|
|
|
|
|
NOTE: To use your paralleled generators to provide backup power to a home or other dwelling, or an RV, you will need an adapter cord to run from the
DO YOU NEED A TRANSFER SWITCH OR OTHER ACCESSORIES?
Parallel Power Kit (use 10/3 or 10/4 cord) with an appropriate female connector to plug into your power inlet box, transfer switch or RV. A transfer switch is required by the National Electrical Code Article 702.6 for all backup generator installations.
Transfer Switch GenTran Model 300660
or
301060
30 Amp 125V
Power Inlet Box
GenTran 05302
Or
30 amp 125/250V Power Inlet Box GenTran 14302
CORD REQUIRES
Female Conn.
GenTran Part
RJBC530
or
RJBC1430
Depending on transfer switch or power inlet box model
REQUIRES
Male Plug
50 amp 125 V GenTran Part RJBP6361 Honda Code 6363550
**Use 10/4 or 10/3 Cord **
WARNING: Hazardous voltages present when generators running. Will cause death, serious injury or substantial property damage. Shut
off generators before connecting to or disconnecting from Parallel kit. IMPORTANT: The accessories noted here are intended for 120 volt use only. Transfer switches and power inlet boxes should be installed by a qualified professional familiar with residential wiring and electrical codes. Gen/Tran accepts no responsibility for accidents caused by incorrect or in appropriate installation or use of this product.