Generac Power Systems Transfer Switches and Accessories manual LIQUID-COOLED generators, J, K

Page 13

ProductGenerac Selection- Life is betterGuidewith power.

LIQUID-COOLED generators

To build a generator and transfer switch, specify each ordering option below.

Generator voltage ratings must match transfer switch voltage.

 

 

 

 

 

 

Step 1

 

Step 2

Step 3

Step 4

Step 5

Step 6

 

 

 

 

 

 

kW Ratings

 

Engine

Voltage

 

Fuel

Enclosure

Emission/

 

 

 

 

 

e.g. (45 kW = 045)

e.g. (5.4L = 54)

120/240 1ø = A

Natural Gas = N

Steel = S

Catalytic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120/208 3ø = G

Propane Vapor = V

Aluminum = A

Converter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120/240 3ø = J

Field Convertable

 

 

 

 

No Catalyst = N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

277/480 3ø = K

to LP = *

 

 

 

 

1Catalyst & A/F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ratio = Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

 

 

 

2.4L @ 1800 RPM

 

A,G,J

 

 

N*

 

 

A

 

N/A

 

 

 

 

 

25

 

 

 

1.6L @ 3600 RPM

 

A,G,J

 

 

N*

 

 

S

 

N/A

 

All

27

 

 

 

2.4L @ 1800 RPM

 

A,G,J

 

 

N*

 

 

A

 

N/A

 

30

 

 

 

1.6L @ 3600 RPM

 

A,G,J

 

 

N*

 

 

S

 

N/A

 

models

36

 

 

 

2.4L @ 1800 RPM

A, G, J, K

 

 

N*

 

 

A

 

N/A

 

begin

45

 

 

 

2.4L @ 3600 RPM

A, G, J, K

 

 

N*

 

 

S

 

N, Y

 

with QT

48

 

 

 

4.2L @ 1800 RPM

A, G, J, K

 

 

N*

 

 

A

 

N, Y

 

 

 

 

 

60

 

 

 

2.4L @ 3600 RPM

A, G, J, K

 

 

N

 

 

S

 

N

 

 

 

 

 

60

 

 

 

2.4L @ 3600 RPM

A, G, J, K

 

 

V

 

 

S

 

N

 

 

 

 

 

70

 

 

 

6.8L @ 3600 RPM

A, G, J, K

 

N, V

 

S, A

 

N

 

 

 

 

 

80

 

 

 

4.6L @ 3600 RPM

A, G, J, K

 

N, V

 

S, A

 

N

 

sample

100

 

 

6.8L @ 2300 RPM Gear Drive

A, G, J, K

 

N, V

 

S, A

 

N, Y

 

130

 

 

6.8L @ 3000 RPM Gear Drive

A, G, J, K

 

N, V

 

S, A

 

N, Y

 

 

 

 

 

150

 

 

6.8L @ 3600 RPM

A, G, J, K

 

N, V

 

S, A

 

N, Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q

 

T

 

 

0

 

6

 

0

 

 

2

 

4

 

 

K

 

 

N

 

 

S

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q T

Model Number (Enter on Order Form) 1 = Catalyst & A/F Ratio may not be available for all models. Contact Your Generac representative for more information.

transfer switches

 

 

 

 

 

Step 1

Step 2

 

 

 

Step 3

Step 4

Step 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Selection Criteria

 

Transfer Switch

Switch Type

 

Amp Rating

Voltage

Enclosure Type3,4

 

 

 

R Controller = RTS

Normal = N

 

e.g. (200 Amp = 200)

120/240 1ø = A

NEMA 1 = 1

 

 

 

H-100 Controller = HTS

Service Entrance Rated1 = E

 

 

 

 

 

 

 

 

 

 

 

 

 

120/208 3ø = G

NEMA 3R = 3

 

 

 

Load Shedding2 = S

8 cct. Integrated Load Center2 = D

 

 

 

 

 

 

 

 

 

 

 

 

120/240 3ø = J

NEMA 12 = 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 cct. Integrated Load Center2 = F

 

 

 

 

 

 

 

 

 

 

 

 

277/480 3ø = K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12 cct. Integrated Load Center2 = H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14 cct. Integrated Load Center2 = P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16 cct. Integrated Load Center2 = W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16 cct. Priority Load Center,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Load Shedding3 = S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For Standby

 

RTS

 

 

 

 

 

 

 

 

n, e, d, f, h, p, w, s

 

100, 200, 400

 

 

A, G, J, K

1, 3

 

 

Generators

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8 - 60 kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For Standby

 

HTS

 

 

 

 

 

 

 

 

 

n

 

100, 150, 200,

 

 

A, G, J, K

1, 3, 4

 

Generators

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400, 600, 800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

70 - 150 kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

0

 

0

 

 

 

 

G

 

 

3

 

 

 

 

 

R

 

 

T

 

S

 

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

sample

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Product Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Enter on Order Form)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 = 120/240 1ø, NEMA 3R Only

 

 

2 = 200 Amp service entrance rated NEMA 3R

3 = HTS 100 - 400 Amp NEMA 1/3R Only

 

 

4 = HTS 600 - 800 Amp NEMA 12/3R Only

14

Image 13
Contents Residential Commercial Light Industrial Standby GeneratorsPower to go wherever you need it 24/7 power protection from damaging power outagesMore Choices Whole-House Protection How Much Power Do You Need?Sizing Guide 17-20 kW 17 kWAir-cooled 8 20 kW Generac Air-cooled Models22-60 kW Quiet standard in liquid-cooled automatic standby power70-150 kW Liquid-cooled 22 150 kWIndustrial Power from Generac’s Modular Power Systems Modular Power Systems Gemini Bi-FuelBi-fuel­ Longest Run Times in the IndustryGp series Xp seriesPortable 1800 17500 Watts Xp series 4000 10000 WattsPowerManager Load Shedding Transfer Switch Automatic Transfer SwitchesRTS Transfer Switches Distributed Load CenterHTS Transfer Switches Future in generator installationFeatures include GenReady Load CenterAccessories AccessoriesProduct Specifications Transfer switcHesPortable Air-CooledLiquid-CooledLIQUID-COOLED generators Transfer switchesJ, K Product NumberTradition of Quality and Innovation Commitment to serviceMyGenerac.com