Enviro 170S5FG manual Metric Conversion Chart, MQL Metric Conversion

Page 28

MQL • METRIC CONVERSION

Metric Conversion Chart

SI UNIT

CONVERSION

= ENGLISH UNIT

CONVERSION

= SI

 

SI UNIT

 

CONVERSION

= ENGLISH

 

CONVERSION

= SI

FACTOR

FACTOR

UNIT

 

 

FACTOR

UNIT

 

FACTOR

UNIT

 

 

 

 

 

 

 

 

 

Area

 

 

 

 

 

 

 

Temperature Interval

 

cm2

 

 

 

100

mm2

 

°C

 

 

1.8

°F

 

0.5556

°C

cm2

0.1550

in2

 

645.2

mm2

 

 

 

 

 

Velocity

 

 

 

m2

10.76

ft2

 

0.09290

m2

 

m/s

 

 

3.281

ft/s

 

0.3048

m/s

 

 

Length

 

 

 

 

m/s

 

 

196.9

ft/min

 

0.00508

m/s

mm

0.03937

in.

 

25.4

mm

 

 

 

 

 

Volume

 

 

 

mm

0.003281

ft.

 

304.8

mm

 

mm3

 

 

 

 

 

1.0x10-6

L

m

3.281

ft.

 

0.3048

m

 

mm3

 

6.102x10-5

in.3

 

0.01639

L

m

1.094

yd.

 

0.9144

m

 

L

 

0.03531

ft3

 

28.32

L

 

 

Mass

 

 

 

 

m3

 

 

1.308

yd3

 

0.7646

m3

g

0.03527

oz.

 

28.35

g

 

L

 

 

0.2642

U.S. gal

 

3.785

L

kg

2.205

lb.

 

0.4536

kg

 

L

 

 

2.113

U.S. pint

 

0.4732

L

tonne, Mg

1.102

U.S. ton (2000 lb.)

0.9072

tonne, Mg

 

mL, cm3

 

0.03381

U.S. oz

 

29.57

mL

 

 

Power

 

 

 

 

 

 

 

Volume / Time

 

 

 

kcal/h

 

 

 

1.163

W

 

m3/h

 

 

 

 

 

0.2778

L/s

kcal/h

3.968

Btu/h

 

0.2931

W

 

m3/h

 

 

0.5886

ft3/min

 

0.4719

L/s

HP metric

 

 

 

0.7355

kW

 

m3/h

 

 

4.403

U.S. gal/min

0.06309

L/s

HP metric

0.9863

HP (550 ft. lb.

)

0.7457

kW

 

L/h

 

 

 

 

 

2.778x10-4

L/s

 

 

S

 

 

 

 

 

 

 

 

 

 

 

 

Mcal/h

 

 

 

1.163

kW

 

L/h

 

4.403x10-3

U.S. gal/min

0.06309

L/s

Mcal/h

0.3307

Ton refr.

 

3.517

kW

 

(m3/h)/

 

 

1.780

cfm/ton

 

0.1342

L/s - kW

 

 

Pressure

 

 

 

(1000 kcal/h)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mm w.g. 4°C

 

 

 

9.806

Pa

 

 

 

 

 

 

 

 

 

mm w.g. 4°C

0.03937

in H2O 39.2°F

 

249.1

Pa

 

 

 

 

 

 

 

 

 

mm Hg 0°C

 

 

 

0.1333

kPa

 

SI UNIT

 

CONVERSION

= ENGLISH

 

CONVERSION

= SI

mm Hg 0°C

0.03937

in Hg 32°F

 

3.386

kPa

 

 

FACTOR

UNIT

 

FACTOR

UNIT

 

 

 

 

 

kgf /cm2

 

 

 

98.07

kPa

 

 

 

 

Temperature

 

 

 

kgf /cm2

14.22

psi

 

6.895

kPa

 

°C

 

 

 

 

 

°C + 273.15

°K

mH2O

3.281

ft H2O

 

2.989

kPa

 

°C

 

(°C x 1.8) + 32

°F

 

(°F - 32) ÷ 1.8

°C

PREFIXES

 

 

 

LEGEND

 

 

 

 

 

UNITS

 

 

 

M

MEGA-

106

 

m

METER

 

 

 

HP metric = METRIC

 

k

KILO-

103

 

cal

CALORIE

 

 

 

 

 

HORSEPOWER

d

DECI

10-1

 

kg

KILOGRAM (mass)

 

mm w.g.

MILLIMETERS

c

CENTI

10-2

 

kgf

KILOGRAM — FORCE

 

 

WATER GAUGE

m

MILLI

10-3

 

kp

KILOGRAM — FORCE

mmCE

MILLIMETERS

 

 

 

 

L

LITER

 

 

 

 

 

WATER GAUGE

 

 

 

 

°C

DEGREES CELSIUS

 

mmHg

MILLIMETERS

 

 

 

 

K

KELVIN

 

 

 

 

 

MERCURY

 

 

 

 

 

W

WATT

 

 

 

tonne =

1000 kg

 

 

 

 

 

Pa

PASCAL

 

 

 

kcal =

KILOCALORIES

 

 

 

 

J

JOULE

 

 

 

bar =

100 kPa

 

 

 

 

 

N

NEWTON

 

 

 

 

 

 

 

 

 

 

 

 

h

HOUR

 

 

 

 

 

 

 

 

 

 

 

 

m

MINUTE

 

 

 

 

 

 

 

 

 

 

 

 

s

SECOND

 

 

 

 

 

 

 

 

 

 

 

 

g

GRAM

 

 

 

 

 

 

 

 

28

ENVIRO-TEC

Image 28
Contents Page MQL Table of Contents Standard Features Product Overview MQLMQL Features and Benefits Constant volume applications Application Considerations MQLMQL Unit Configuration Unit Configuration in Direction of AirflowElectric Heat MQL Airflow Blow ThruAirflow Draw ThruVoltage Phase MQL Electric HeatCoil and Filter Data MQL Coil and Filter DataSection Pressure Drops MQL Static Pressure DataCoil Pressure Drops Filter Pressure DropsStatic Pressure Data MQL Coil Weight Data MQL Weight DataMotor/Drive Weight Data Weight and Electrical Data MQLMotor Electrical Data General Fan NotesForward Curved Fan Performance Data MQL FAN Performance DataPlug Fan Performance Data FAN Performance Data MQLMQL02 Fan 09-04 Class MQL03 Fan 09-06 ClassMQL FAN Performance Curves CFM x SP BHPMQL06 Fan 12-09 Class MQL04 Fan 10-07 ClassSE = CFM x SP MQL08 Fan 12-12 Class MQL10 Fan 15-11 Class IMQL14 Fan 18-18 Class I MQL12 Fan 18-13 Class IFAN Performance Curves MQL MQL02 Plug Fan MQL17 Fan 18-18 Class I= CFM x SP MQL03 Plug Fan MQL04 Plug FanMQL08 Plug Fan MQL06 Plug FanCFM x SP MQL10 Plug Fan MQL12 Plug FanMQL14 Plug Fan MQL17 Plug FanGuide Specifications MQL Guide Specifications Blower Coil UnitMQL Guide Specifications Guide Specifications MQL Metric Conversion Chart MQL Metric ConversionENVIRO-TEC MQL Standard & Optional Features

170S5FG specifications

The Enviro 170S5FG is a cutting-edge hybrid vehicle from the renowned Enviro brand, designed to meet the evolving demands of public transportation while prioritizing sustainability and passenger comfort. One of the standout features of the Enviro 170S5FG is its hybrid powertrain, which effectively combines a diesel engine with an electric motor. This dual system significantly reduces emissions while ensuring optimal fuel efficiency. The vehicle is engineered to operate in various urban settings, making it an ideal choice for cities aiming to enhance their environmental impact.

In terms of performance, the 170S5FG boasts impressive acceleration and smooth operations, thanks to its state-of-the-art torque management system. The hybrid technology ensures that the vehicle can switch seamlessly between electric and diesel power, allowing it to conserve energy during low-speed travel, such as in stop-and-go traffic. This feature is particularly beneficial for reducing urban air pollution, as the vehicle emits fewer greenhouse gases compared to traditional diesel-only buses.

Passenger comfort is a priority in the Enviro 170S5FG, reflected in its thoughtfully designed interior. The spacious cabin can accommodate a significant number of passengers, with comfortable seating arrangements and ample standing room. Large windows provide natural light and enhance the overall travel experience. Additionally, the focus on accessibility means that the vehicle is equipped with features such as low floors, ramps, and designated spaces for wheelchairs, ensuring that it caters to all members of the community.

Safety comprises another area of excellence for the Enviro 170S5FG. Equipped with advanced safety technologies, including electronic stability control, anti-lock braking systems, and high-visibility LED lighting, the vehicle prioritizes the protection of passengers and drivers alike. The ergonomic design also includes enhanced visibility for the driver, contributing to safer navigation in complex urban environments.

Moreover, the Enviro 170S5FG incorporates intelligent connectivity features that enhance operational efficiency and passenger convenience. These technologies support real-time tracking and monitoring of bus performance, allowing transit authorities to optimize routes and schedules effectively.

In summary, the Enviro 170S5FG is a forward-thinking solution that combines hybrid technology, passenger-centric design, and advanced safety features. Its commitment to sustainability, performance, and comfort makes it an ideal asset for modern public transportation systems aiming to create greener cities while enhancing the commuter experience.