Dynasty Spas Premier System D-2000 Standard, Economy, Flow, Ice, Sensor 1Spa is deactivated

Page 18

To p S i d e C o n t r o l I n s t r u c t i o n s

Diagnostic Messages

O H

Overheat Protection (Spa is deactivated)

DO NOT ENTER THE WATER. If the spa water has reached 112 F, remove

 

the spa cover to cool the water. Overheating may occur if the filter cycle

 

is set too long. At 110 F, the spa should reset itself. If the high limit sensor

 

detects 118 F at the heater, the spa will shut down. When the heater

 

cools to 110 F, press any button to reset the spa. If the spa will not

 

reset, then shut off power to the spa and call your dealer or service

 

organization.

StAn

EcoN

Standard

The spa is in standard mode and will continually heat to the set temperature.

Economy

The spa is in economy mode. ECON is flashed alternately with COOL and the current spa temperature and when the spa water is more than 20F cooler than the set temperature. The circulation pump and heater will operate to warm the water to within 15F of the set temperature.

FLO

Flow

 

Flashing alternately with temperature. The filter may need cleaning.

 

The water level is too low. Be sure flow valves are open. Bleed

 

Circulation Pump if needed. FLO (NOT FLASHING) a pressure

 

switch has malfunctioned. Contact your dealer or service organization.

COOL Cool

 

The spa water is more than 20 F cooler than the temperature last

 

set. No action is required. Spa is functioning properly. The circulation

 

pump and heater will operate to warm the water to within 15 F of the

 

set temperature.

ice

Ice

 

If the high limit sensor detects 40 F at the heater, then the pumps

 

and blower (if installed) automatically activates to provide freeze

 

protection. The equipment stays on until the sensor detects 45 F at the

 

heater. Freeze protection is activated regardless of the spa's status.

 

In colder climates, an optional additional freeze sensor may be added

 

to protect against freeze conditions. See your dealer for details.

S n 1

Sensor 1(Spa is deactivated)

The high-limit sensor or water temperature sensor is not working. Call

 

your dealer or service organization.

S n 3

Sensor 3(Spa is deactivated)

The main sensor is not working. Call your dealer or service organization.

18

Image 18
Contents Page Installer DealerDyynnaassttyy SSppaass Ownneerrss Maannuuaall Dear Dynasty Spa Owner P o r t a n t S a f e t y I n s t r u c t i o n s SPA & Pool Institute S i c I n t r o d u c t o r y I n f o r m a t i o n T u p & D e l i v e r y G u i d e l i n e s T u p & D e l i v e r y G u i d e l i n e s Factory Recommended G.F.C.I Load Center Wiring R i n g D i a g r a mN e r a l P r e O p e r a t i o n I n s t r u c t i o n s To p S i d e C o n t r o l I n s t r u c t i o n s Preset Filter Cycles Diagnostic MessagesFreeze Protection Preset Filter Cycles Auxiliary Panel optional System auxiliary panel optional Blower optional Standard and Economy ModeCirculation Pump optional LightFlow StandardEconomy IceMini Diverter Valve Lt e r L o c a t i o n Single FilterDual Filter Cleaning and Replacing Filter Cartridge Lt e r M a i n t e n a n c eCleaning Your Spa Water Filling Spa With WaterWater Testing BalanceAn Overview Monthly For Equipment Protection As NeededAn Overview As Needed Skin ConditioningAlgae Control A i n i n g Yo u r S p a Winterize Your SPA N t e r i z i n g Yo u r S p aAsk Your Dealer About Using a Cover Caddy N t e r i z i n g S p a C o v e r sJets wont come on Spa Lights wont come onPump will not prime No heat or heat too lowMotor does not run Low water flowSpa is leaking Motor runs hotO s s a r y o f T e r m s Air Blower Air Loop Air Venturi CabinetO s s a r y o f T e r m s c o n t SkimmerA M o d e l s D e t a i l R e f e r e n c e C h a r t