Dimplex Shower Final assembly and commissioning, Riser rail, Electrical, Commissioning the shower

Page 4

Dimp13292-Shower inst aX4 5/5/04 2:08 pm Page 7

INSTALLATION

INSTALLATION / FINAL ASSEMBLY AND COMMISSIONING

Riser rail

1

 

7

Part the mounting bracket assembly so that the fixing plate is separate from the cover. Establish the best position for the riser rail, and mark the wall for the lower mounting bracket.

Make allowances for the tallest person likely to use the shower regularly.

Insert the rail into the bottom and top brackets and screw the upper mounting bracket in place. Clip the end caps onto the mounting brackets.

The cable should be routed to the shower unit from either the top, bottom or back of the shower unit. This cable should be hidden from view.

Connect the brown live wire to the terminal marked L

Connect the blue neutral wire to the terminal marked N

2)

Fit the flexible hose to the shower unit

 

and remove the showerhead.

3)

Turn the temperature control knob at

 

the bottom of the unit fully

 

anti-clockwise.

4)

Turn on the power at the isolating

 

switch.

2

When drilling through tiles use a suitable glass or tile drill of 6mm diameter to drill through the tile only. Use a no 10/5.5mm masonry drill to make a hole 35mm deep, and fit the wall plug. (NB some

wall constructions may require the use of different types of wall fixings to those supplied). Screw the lower bracket base to the wall.

3

Locate the crimped end of the riser rail (Figure 4) into the mounting bracket, then fit the upper bracket to the rail. Ensure the rail is vertical, then mark the wall for the fixing.

4

NOTE if it is necessary to shorten the rail, use a junior hacksaw to cut the excess material from the plain end of the rail (the uncrimped end).

5

Insert the end pieces of the height adjuster into the body section matching the letters A and B (moulded into the ends of each piece) and twist so the pieces lock together.

6

With the shower head holder in the upright position (widest

opening at the top) and the lever in the open position, slide

the assembly onto the rail. Tighten the height adjuster to

the rail by twisting the lever.

6

Electrical

Switch off the water supply at the isolating valve before connecting the wiring to the unit.

The shower unit must be permanently connected to the electricity supply, direct from the consumer unit via a double pole linked switch with a minimum contact gap of 3mm.

It is recommended that the switch be a cord operated type with neon on/off indicator, otherwise the switch should be readily accessible, clearly identifiable and out of reach of any person using the shower. The wiring to the switch must be done without the use of a plug or socket outlet.

The cable used must be of a diameter suitable for the power rating of the shower selected. The table below may be used as a guide to the cable requirements. If in doubt consult a qualified electrician.

kW rating

Minimum

Fuse rating

Max cable length

Isolating

switch (Amps)

(Amps)

Consumer unit to

 

 

 

shower (m)

 

 

 

 

 

 

 

 

6mm cable

10mm cable

7.5

40

40

27

44

8.5

40

40

23

38

9.5

40

40

21

32

10.5

45

45

18

30

 

 

 

 

 

Connect the yellow and green earth wire to the terminal marked E on the backplate.

IMPORTANT – ensure the terminal block screws are fully tightened and that no insulation enters the terminal block, preventing a good electrical connection.

To conform to IEE regulations the earth continuity conductor of the electrical installation must be effectively connected to all exposed metal parts of other appliances and services in the room in which the shower unit is installed.

WARNING! Do not attempt to operate the shower unit until the installation is fully complete.

SECTION 3

Final assembly and commissioning

With the unit wired and plumbed correctly the front cover may now be refitted.

1)Place the cover lightly over the shower unit and turn the knobs so that they engage correctly with the spindles. The front cover may then be pressed lightly into place and secured using the two fixing screws.

5) Start the shower by pressing the cold

power selector button. The water

should now begin to flow through the

shower.

Warning do not attempt to select any other

setting other than Cold at this stage.

6)Once a steady stream of water is achieved from the outlet of the shower unit stop the shower by pressing the STOP button.

7)Pass the hose through the hole in the soap dish and refit the shower head.

8)Fit the handset into the height adjuster and clip the soap dish onto the riser rail.

The unit is now ready for commissioning.

Commissioning the shower

Important: The shower unit must be full of water before power (heat) settings are used.

1)With the water supply to the unit turned on, turn the bottom temperature control knob anti-clockwise to the full cold position. No water should exit the shower either from the handset or from any other part of the shower unit.

7

Image 4
Contents Shower User Guide Installation Unpacking and important notices610mm 218mm 339mmGeneral Planning the installationPlumbing Final assembly and commissioning Setting other than Cold at this stageRiser rail ElectricalLooking after your shower OperationCooler Warmer Trouble shooting Maintenance

Shower specifications

Dimplex Shower is a revolutionary approach to enhancing your bathing experience, combining cutting-edge technology with user-friendly features to provide optimum comfort. One of the main highlights of Dimplex Shower is its smart heating system, which allows for instant hot water on demand. This innovative system eliminates the waiting time for water to reach the desired temperature, ensuring you enjoy a warm shower immediately.

The Dimplex Shower features a sleek, modern design that can seamlessly fit into any bathroom aesthetic. With a minimalistic look, it enhances the overall appeal of your space while offering high efficiency. Available in various models, users can select an option that best matches their needs and preferences.

One of the standout technologies integrated into the Dimplex Shower is its precise temperature control mechanism. This enables users to set their preferred temperature easily, resulting in a consistently comfortable showering experience. The temperature stability feature minimizes fluctuations, allowing you to concentrate on relaxation without interruptions.

Energy efficiency is another significant aspect of Dimplex Shower. Utilizing advanced insulation technologies, these showers minimize energy loss while heating water. The result is a more sustainable and cost-effective solution for daily bathing, allowing consumers to enjoy luxury without compromising their energy bills.

Additionally, Dimplex Shower incorporates user-friendly digital controls that simplify operation. With its intuitive interface, users can customize their shower experience, from water pressure to temperature settings, all at the touch of a button. The LED display provides clear visual feedback, ensuring users are always informed about their shower settings.

Safety is paramount, and Dimplex Shower addresses this with built-in anti-scald technology. This feature prevents water from exceeding safe temperatures, providing peace of mind for families and ensuring a safe experience for children and elderly users.

Finally, easy installation and maintenance further distinguish the Dimplex Shower from competitors. It is designed for straightforward setup, and the high-quality materials used facilitate long-lasting performance. In summary, Dimplex Shower represents a blend of style, efficiency, and innovation, delivering a superior showering experience tailored to modern lifestyles.