Desa PL15EA, PV15EA, PG15EA service manual Reassembly Points, Foam Gasket

Page 8

REASSEMBLY POINTS

Because this is an outdoor product where the control of water is important, the following steps for assembly must be followed.

1.The closed cell foam gasket must seal the hex shaped pan to the inside of the plastic housing (see Figure 8). The seal is to be completely even in the corners of joined parts.

2.The tubular heating element rubber sealing washers must be against the top surface of the steel pan and under the brass flat washers as shown in Figure 9. Nuts on opposite side of pan must be tightened 1/2 turn past finger tight.

3.Apply a SMALL drop of thread locking seal- ant (rated to 300° F, such as Loctite Thread Locker Blue) to each of the thermal reset switch mounting screws (see Figure 10). Torque screws to 6 to 9 inch-pounds.

4.The tip switch cover must isolate tip switch from metal base as shown in Figure 11.

5.To complete grounding of heater, all ground wires must be fixed with screws as originally assembled by the manufacturer. Additionally, internal tooth washers must be against the steel pan and under nuts as shown in Figure 12, for the tubular heating element.

6.No wires should be seen through openings in bottom of heater (see Figure 13).

Figure 8 - Foam Gasket

Figure 10 - Thermal Reset Switch

Mounting Screws

Figure 11 - Tip Switch Cover

Figure 12 - Grounding of the Tubular

Heating Element

Brass Flat

Rubber

Washer

Sealing

 

 

Washer

Figure 13 - Air Openings in Bottom of

Figure 9 - Tubular Heating ElementHeater

Sealing Washers

8

www.desatech.com

115423-01A

Image 8
Contents Table of Contents Do not operate this product in the rain Safety InformationDo not run cord through doorways, holes in floors or walls Ground Fault Interrupter PRE-OPERATING InstructionsPlug Adapter Save these instructions for future referenceGeneral Information Product IdentificationInstallation Wiring Diagram CleaningSafety Requirements OperationTroubleshooting Thermal Limit SwitchALL Systems Working Together Tubular heating element a warms the sur- rounding airObserved Fault Remove obstruction. Clean heaterVary due to element temperature Tom of heater see ,Reassembly Points Foam GasketReflective Tape and Louvers Illustrated Parts Breakdown Parts List Industrial Drive P.O. Box