Troubleshooting Guide

 

 

 

 

 

 

 

 

 

Symptom

Cause(s)

Action(s)

 

 

 

·

No power on outlet

· Repair outlet problem or use another outlet

 

 

 

·

Blown fuse

· Replace blown fuse with same type and rating

 

 

 

fuse

 

 

 

 

 

 

Fixture does not power up

·

Bad power cord/plug

·

Repair or replace power cord/plug

 

 

·

Bad power switch

·

Replace power switch

 

 

·

Bad power supply

·

Replace power supply

 

 

·

Bad main controller

·

Replace main controller

 

 

 

 

 

 

 

 

· State/Power On parameter set to

· Change parameter to YES

 

Fixture powers up but

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

lamp does not ignite

·

Lamp temperature problems

·

Check error messages and follow instructions

 

 

·

Lamp problems

·

Check error messages and follow instructions

 

 

 

 

 

 

 

 

 

·

Dimmer not at full output

·

Adjust dimmer value

 

 

·

Lamp still cold

·

Wait for lamp to come up with full output

 

 

 

temperature

 

 

 

 

 

 

Lamp ignited but has low

·

CTC or CMY filter interfering

·

Set color wheel or filter to home position

 

intensity/color

·

Defective or old lamp

·

Replace lamp

 

temperature

 

 

 

 

 

 

 

 

·

Misaligned lamp

·

Realign lamp

 

 

·

Defective lamp wires or socket

· Repair/change wiring or socket

 

 

·

Defective ballast

·

Replace ballast

 

 

 

 

 

 

 

 

 

·

Defective or old lamp

·

Replace lamp

 

Lamp flickers or turns off

·

Temperature problems

·

Check error messages and follow instructions

 

by itself

·

Defective lamp wires or socket

· Repair/change wiring or socket

 

 

 

 

·

Defective ballast

·

Replace ballast

 

 

 

 

 

 

 

 

Circuit breaker/fuse keeps

·

Excessive circuit load

·

Check total load placed on the electrical circuit

 

tripping/blowing

·

Short circuit along the power wires

· Check for a short in the electrical wiring

 

 

 

 

 

 

 

 

 

 

·

Wrong DMX addressing

· Check DMX mode and starting DMX address

 

Fixture does not respond

·

Damaged DMX cables

·

Check DMX cables

 

·

Wrong polarity on the controller

·

Check polarity switch settings on the controller

 

to DMX when nearby

 

fixtures on the same

·

Loose DMX cables

·

Check cable connections

 

universe do

 

·

Faulty DMX interface

·

Replace the Main board

 

 

 

 

·

Faulty Display/Main board

·

Replace the Main board

 

 

 

 

 

 

 

 

 

·

Non DMX cables

·

Use only DMX compatible cables

 

 

·

Bouncing signals

·

Install terminator as suggested

 

DMX signal problems

·

Long cable / low level signal

·

Install an optically coupled DMX splitter right after

 

 

the fixture with the strong signal

 

(see Appendix > DMX

 

 

 

 

 

 

 

 

 

 

Primer)

·

Too many fixtures

·

Install an optically coupled DMX splitter after unit

 

 

 

#32 or before

 

 

 

 

 

 

 

· Interference from AC wires

·

Keep DMX cables separated from power cables or

 

 

 

fluorescent/black lights

 

 

 

 

 

If you still experience technical problems after trying the above solutions, contact CHAUVET® Technical Support.

Legend 300E Spot User Manual Rev. 01g

-27-

Image 31
Contents Page Author Editor Manager PD Manager Copyright 2010 ChauvetTable of Contents Table of Contents Convention Meaning What is IncludedBefore You Begin Icon MeaningPersonal Safety Safety NotesMounting and Rigging Power and Wiring Operation Additional Features Options Product Description FeaturesIntroduction Mode DMX Channel SummaryProduct Overview AC Power SetupDMX Linking Extra Gobos Color Wheel Gobo WheelsRotating Gobos Gobo Replacement Diagram ProcedureIncreasing the Lamp’s Life Lamp Replacement DiagramMounting Procedure Product Mounting DiagramOrientation Rigging Button Function OperationLCD Display Control Options Programming Navigation ButtonsDMX Functions DMX Address DMX Mode View DMX Values DMX SettingsFixture Settings Lamp Settings Automatic fixture test runs only once after activation Display SettingsFixture Tests Automatic Fixture Test Manual Fixture TestYou can leave this sub-menu at any time by pressing Menu Reset FunctionsYou cannot modify or reset the fixture operation timer Fixture InformationEntering Offset Mode Offset ModeSpecial Functions Prism YellowGobo IrisMenu Map DMX Values Channel Function Value Percent/Setting PanFrom the previous Channel Function Value Percent/Setting Mode ContSlow open / fast close 100~0% Color Photometrics Technical InformationError Messages Symptom Causes Actions Troubleshooting GuideContact Us World Headquarters ClaimsPower Technical SpecificationsChauvet
Related manuals
Manual 34 pages 14 Kb Manual 1 pages 13.72 Kb Manual 1 pages 54.37 Kb

300E specifications

The Chauvet 300E is a high-output, versatile lighting fixture that has gained popularity among professionals in the entertainment industry. This unit is primarily designed for stage productions, events, and installations where powerful illumination and dynamic effects are required.

One of the standout features of the Chauvet 300E is its exceptional light output. Equipped with a high-intensity LED source, this fixture delivers vibrant colors and impressive brightness, making it suitable for various environments, from intimate venues to large-scale productions. The lens system enhances the beam angle and distribution, allowing for even coverage and creative lighting designs.

In terms of technology, the Chauvet 300E incorporates advanced DMX control options, ensuring seamless integration with existing lighting systems. With its 3-pin and 5-pin DMX connectors, users can easily connect multiple fixtures and control them from a centralized lighting console. The fixture's user-friendly interface simplifies programming and operation, giving lighting designers the flexibility to create stunning effects effortlessly.

Another noteworthy characteristic of the Chauvet 300E is its durability and robust design. Constructed from high-quality materials, this fixture is built to withstand the rigors of touring and frequent use. The adjustable yoke allows for easy mounting on truss systems or floors, ensuring stability during performances.

The Chauvet 300E also features various built-in lighting effects, including strobing and color mixing capabilities. These effects can be adjusted to suit specific needs, enabling designers to create unique atmospheres tailored to each event. Additionally, its quiet operation makes it ideal for theatrical performances and events where sound levels must be kept to a minimum.

Energy efficiency is another crucial aspect of the Chauvet 300E. The LED technology not only reduces power consumption but also results in lower heat output, enhancing longevity and reducing the need for additional cooling systems.

In conclusion, the Chauvet 300E is a powerful, reliable lighting fixture that combines performance with advanced technology. Its impressive output, flexible control options, durability, and energy efficiency make it an excellent choice for lighting designers and professionals seeking to elevate their productions.