American Standard 7236V.068C, 2422V.068C, 2425V.268C Remote Blower Location Option, Typical View

Page 11

REMOTE BLOWER LOCATION OPTION

IMPORTANT! It is not necessary that the blower motor be relocated. This option is provided for the case that a particular installation makes this effort practical.

NOTE: Relocating blower motor from factory installed location, see photo W, will require disassembly of air blower from mounting board. Keep all hardware for reattachment at new location. Additional hardware will be required depending upon final desired position of air blower. Follow all instructions listed below.

W.

TYPICAL VIEW

NOTE: Installing the blower in a remote location will reduce the system efficiency.

NOTE: Relocating a blower motor still requires a service access for the blower.

NOTE: All materials needed for the relocation must be supplied by the installer. This includes ordering a longer control panel cable (P/N 754025-0071A).

A separate circuit, which must be protected by the Ground Fault Circuit Interrupter (GFCI), is required in the remote location. Electrical connections should be performed by a licensed electrician.

Choose a space as close to the bath as possible so the system works as efficiently as possible. The space must be at least 0 cubic feet and the blower must be mounted at least 2 inches above the floor and 2 inches minimum away from any wall. The blower must NOT be installed in an attic area.

The blower motor must be located within 12 feet of rigid piping from the bath air manifold. This limitation is for the total pipe length and applies to any direction changes and elbows. There can be no more than six changes of direction. There should be as few direction changes as possible and the piping installation must meet all requirements of local plumbing and building codes.

Disconnect the blower from the flexible hose as shown in photo X. Do NOT remove the check valve manifold that is mounted to the underside of the air bath. The manifold MUST remain mounted above the tub overflow level as shown in X.

X.

TYPICAL VIEW

Do NOT move check valve manifold

Use 1 1/2” PVC rigid piping and couplings to extend the blower motor location as shown in photos Y and Z. Detach the flexible hose section from the blower end and extend the air line by adding the appropriate length of PVC piping. Mount the blower in a horizontal direction using the mounting screws provided with the air bath system. Do NOT glue piping to either the manifold or blower. These couplings MUST be attached to the piping with screws as shown in photos Y and Z. Glue only the PVC piping and couplings needed to extend the air line. Let the glued couplings set overnight before attaching the blower and manifold couplings with screws.

CAUTION: It is imperative to let the glued piping set overnight as there may be fumes from the glue that could be ignited if not allowed to dissipate.

Y.

Z.

11

754072-100

Image 11
Contents Installation Guide for Evolution AIR Baths Table of Contents Important Safety Instructions List of Optional Components not Included Deck C Side View END View Drain / OverflowUnderside Water / Floor36 Model 7236V.068C ROUGHING-IN References32 Model 2422V.068C 36 Model 2771V.068CFor Models 2425V.168C-RHO and 2425V.268C-LHO Installation and Framing InstructionsUnder Deck Mounting Instructions Suggested AIR Bath / Bath Installation MethodTypical Flange Mounting Detail Wire Selection Guide AIR Bath Electrical Installation InstructionsHarsh Chemicals should Never be Used on Acrylic Surfaces Post Installation CLEAN-UPCirculation System CLEANING-PURGING Procedures Drain Connection and System TestTypical View Remote Blower Location Option754072-100

7236V.068C, 2645V.068C, 2771V.068C, 2425V.168C, 2425V.268C specifications

American Standard is renowned for its commitment to quality and innovation in bathroom fixtures, and its series of bathroom tubs represents the pinnacle of comfort, style, and efficiency. Among these, the models 2425V.268C, 2771V.068C, 7236V.068C, 2645V.068C, and 2422V.068C stand out for their unique features and cutting-edge technologies.

The 2425V.268C model is designed with a contemporary aesthetic, featuring a sleek rectangular shape that meets every modern bathroom’s design standards. Its high-gloss acrylic surface not only enhances visual appeal but also ensures easy cleaning and resistance to stains and scratches. Complemented by a deep soaking design, the tub allows bathers to immerse themselves in relaxation.

The 2771V.068C is another impressive model that emphasizes ergonomics and comfort. This tub includes an integral lumbar support, making it ideal for long, restorative soaks. Its spacious interior can accommodate two users, perfect for couples looking to unwind together. The model also boasts a slip-resistant surface, ensuring safety without compromising stylishness.

For those seeking versatility, the 7236V.068C is a standout option. This model features a generous size that accommodates both bathing and showering needs, making it suitable for smaller bathrooms. Its stylish ledges provide ample space for shower necessities, while the elegant design maintains an aesthetically pleasing appearance.

The 2645V.068C focuses on maximizing relaxation with its deep design, allowing bathers to fully submerge and escape the stresses of daily life. Engineered with American Standard’s patented EverClean technology, it resists growth of stain and odor-causing bacteria, which helps maintain cleanliness and hygiene.

Lastly, the 2422V.068C model captures attention with its compact yet functional design. Ideal for smaller spaces, it doesn’t skimp on comfort, with a deep basin that encourages extensive relaxation time. This versatile tub can be installed as a drop-in or undermount, adapting to a wide range of bathroom styles.

In sum, American Standard’s 2425V.268C, 2771V.068C, 7236V.068C, 2645V.068C, and 2422V.068C models each boast distinct features, advanced technologies, and thoughtful designs that cater to a variety of consumer preferences, making them top choices for modern bathrooms.