ELLISSE
2705.XXXW
SERIES WHIRLPOOL
HIGH GLOSS ACRYLIC SHOWN LESS ALL FITTINGS
INSTALLATION INSTRUCTIONS
|
|
|
|
| 1524mm |
|
|
| ||
|
|
| 229mm | (60) |
|
| WATER RETENTION | |||
SEE FITTING |
|
|
|
| ||||||
(9) |
|
|
|
|
| |||||
|
|
|
|
| FLANGE (3) SIDES | |||||
SPECS FOR |
|
|
|
|
|
| ||||
19mm |
| FINISHED |
|
|
|
| ||||
DIMENSION |
|
|
|
|
| |||||
| WALL LINE |
|
|
|
| |||||
(3/4) |
|
|
|
|
| |||||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| |
| 387mm |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| PUMP | |||
|
|
|
|
|
|
|
|
| ||
813mm |
|
|
|
|
|
|
|
|
| |
(32) |
|
|
| 229x305mm |
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ||
| C/L OF |
| (9x12) FLOOR |
|
|
|
|
| ||
|
| CUTOUT |
|
|
|
|
| |||
SUPPLIES |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
| |||
|
|
| 51mm |
|
|
|
|
| ON/OFF SWITCH | |
|
|
|
| ALT. PUMP |
|
|
| PROVIDE ACCESS | ||
|
|
| (2) |
|
|
|
| |||
|
|
| C/L OF DRAIN |
| LOCATION |
|
| TO PUMP FOR SERVICING | ||
|
|
| OUTLET |
|
|
|
|
| ON ALL INSTALLATIONS | |
|
|
| C/L OF |
|
|
| FINISHED WALL |
| ||
|
| SHOWER ARM |
| C/L OF |
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||
|
|
| VALVES |
|
|
|
| |||
|
| REMOVABLE BLANK |
|
|
|
|
|
| OPTIONAL | |
| 102mm |
|
| C/L OF |
| WATER | ||||
|
|
|
|
| ||||||
305mm | (4) |
|
|
| SPOUT |
| RETENTION | 38mm | ||
(12) OPT. |
|
|
|
|
|
| FLANGE | |||
TOP |
|
|
|
|
| ■ LEVELING |
| |||
OF |
| 51mm |
|
|
|
| STRINGER | UNDERSIDE | ||
DECK |
|
|
|
|
| |||||
| 95mm (2) | C/L OF |
|
|
| NOT FOR | OF DECK | |||
| OVERFLOW |
|
|
| SUPPORT |
| ||||
546mm |
|
|
|
|
| ROUGH | 533mm |
| ||
|
|
|
|
| FLOOR |
|
| |||
|
| INTEGRAL |
|
|
| (21) |
| |||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
|
|
| FEET |
|
|
|
|
|
|
|
| ROUGH |
|
|
|
|
|
|
| ||
| FLOOR |
| 38mm |
|
| 83mm |
| |||
|
|
| THREADS |
|
|
|
| |||
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
THANK YOU...
for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The whirlpool version is completely assembled with pump, motor, and system piping. All you need to finish the installation are your selected fittings and electrical connections for a whirlpool.
To insure maximum performance and pleasure from this product, please follow the instructions and cautions.
List of Optional Components (not included):
•Apron Kit*
•
* see your American Standard Distributor
List of Required Components (not included):
• | Drain 1583.470* | • Bath Filler* | |
* see your American Standard Distributor | |||
List of Required Tools and Supplies: | |||
Tools | Supplies | ||
• | Level | • | Nails |
• | Tape Measure | • | Putty |
• | Pipe Wrench | • | Caulking (waterproof) |
• | Slip Joint Pliers | • | 1 x 3 or 2 x 2 |
• | Screw Driver |
| Stringers |
• | Standard | • | Drop Cloth |
| Woodworking Tools | • | 15 or 20 amp GFCI |
• | Personal Safety |
| Outlet |
| Equipment | • | Cement, Plaster, |
• | Caulking Gun |
| Grout |
GENERAL INSTALLATION INFORMATION
TAILPIECE
GENERAL SPECIFICATIONS FOR 2703/5 WHIRLPOOL
INSTALLED SIZE |
|
|
|
|
|
|
|
| 60 x 32 x | ||||||||||||||
WEIGHT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 141 Lbs. (63 Kg.) | ||||||
WEIGHT w/WATER |
|
|
|
|
|
|
|
| 643 Lbs. (292 Kg.) | ||||||||||||||
GAL. TO OVERFLOW |
|
|
|
|
|
|
|
|
|
| 60 Gal. (277 L) | ||||||||||||
WHIRLPOOL MIN. OPERATING VOL. |
|
|
|
|
|
|
|
| 50 Gal. (189 L) | ||||||||||||||
|
|
|
|
|
|
|
| ||||||||||||||||
BATHING WELL AT SUMP |
|
|
| ||||||||||||||||||||
BATHING WELL AT RIM |
|
|
| 58 X | |||||||||||||||||||
WATER DEPTH TO OVERFLOW |
|
|
|
|
|
| |||||||||||||||||
|
|
|
|
|
| ||||||||||||||||||
FLOOR LOADING |
|
|
|
|
| 48 Lbs./Sq.Ft. (231 Kgs./Sq.m) | |||||||||||||||||
(PROJECTED AREA) |
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
PTS. |
|
|
|
|
|
| 20.8 | ||||||||||||||||
CUBE (FT3) |
|
|
|
| 35.3 | ||||||||||||||||||
|
|
|
| ||||||||||||||||||||
|
|
| WHIRLPOOL ELECTRICAL SPECIFICATIONS | ||||||||||||||||||||
SYSTEM I PUMP |
|
|
|
|
|
| 1.6 HP, 9.7 AMPS, 120V. | ||||||||||||||||
|
|
|
|
| |||||||||||||||||||
SYSTEM II PUMP |
|
|
|
|
|
| 2.1 HP, 15.6 AMPS, 120V. | ||||||||||||||||
|
|
|
|
|
|
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before enclosing with wallboard, tile, etc., water test the unit and check for leaks.
If a whirlpool, do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead (required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping har- ness at any time.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
© American Standard Inc. 2003