Krell Industries RC-5 Word 12 Main Zone Balance/Compression Mode, Word 13 Room EQ/Zone 2 Balance

Page 15

RS-232 Status Block Descriptions, continued

Word 12: Main Zone Balance/Compression Mode

Bit

 

7

 

 

6

 

 

5

4

 

 

3

2

1

0

Description

 

Reserved

 

CMode 1

 

CMode 0

BAL 4

 

BAL 3

BAL 2

BAL 1

BAL 0

 

Bits 4 - 0: Balance Setting 0 – 26

 

 

 

 

 

 

 

 

Bits 5 – 6: Compression Mode

 

 

 

 

 

 

 

 

 

Balance Settings

 

 

 

 

 

 

 

 

 

 

0

Right

Off

9

Left

+2.0

18

Right

+2.5

 

 

 

1

Left

+6

10

Left

+1.5

19

Right

+3.0

 

 

 

2

Left

+5.5

11

Left

+1.0

20

Right

+3.5

 

 

 

3

Left

+5.0

12

Left

+0.5

21

Right

+4.0

 

 

 

4

Left

+4.5

13

Centered 0

22

Right

+4.5

 

 

 

5

Left

+4.0

14

Right

+0.5

23

Right

+5.0

 

 

 

6

Left

+3.5

15

Right

+1.0

24

Right

+5.5

 

 

 

7

Left

+3.0

16

Right

+1.5

25

Right

+6.0

 

 

 

8

Left

+2.5

17

Right

+2.0

26

Left

Off

 

 

 

 

Compression Modes

 

 

 

 

 

 

 

 

 

 

1

Max

 

 

2

Normal

3

Night

 

 

 

 

Word 13: Room EQ/Zone 2 Balance

Bit

7

6

5

4

3

2

1

0

Description

Room EQ 2

Room EQ 1

Room EQ 0

BAL 4

BAL 3

BAL 2

BAL 1

BAL 0

Bits 7 – 5: Room EQ Setting

Room EQ Setting

0Room EQ OFF

1Room EQ Memory 1

2Room EQ Memory 2

3Room EQ Memory 3

4Room EQ Memory 4

Bits 4 - 0: Balance Setting 0 – 26

Balance Settings

 

 

 

 

 

 

0

Right

Off

9

Left

+2.0

18

Right

+2.5

1

Left

+6

10

Left

+1.5

19

Right

+3.0

2

Left

+5.5

11

Left

+1.0

20

Right

+3.5

3

Left

+5.0

12

Left

+0.5

21

Right

+4.0

4

Left

+4.5

13

Centered 0

22

Right

+4.5

5

Left

+4.0

14

Right

+0.5

23

Right

+5.0

6

Left

+3.5

15

Right

+1.0

24

Right

+5.5

7

Left

+3.0

16

Right

+1.5

25

Right

+6.0

8

Left

+2.5

17

Right

+2.0

26

Left

Off

Krell Home Theater Standard 7.1 Developer’s Reference

15

Image 15
Contents Surround Preamp/Processor Developer’s ReferenceSurround Preamp/Processor Developer’s Reference Home Theater StandardOverview RS-232 Port Protocols Connecting to the RS-232 PortCommand RS-232 Code RS-232 Commands for the Home Theater StandardWorks on current zone RS-232 Commands for the Home Theater StandardMain Zone Direct Select Commands Trigger Decode Mode Select Commands Audio Decode Mode Code Word 2 General Status Word 1 Start of MessageRS-232 Status Block Descriptions Word 8 Main Zone Audio Input Word 9 Zone 2 Audio InputWord 10 Loudspeakers / Current Audio Stream Analog and PCM Decode Modes Word 11 Current Audio Decode ModesWord 13 Room EQ/Zone 2 Balance Word 12 Main Zone Balance/Compression ModeWord 14 Center Trim Word 15 Surround TrimWord 16 Back Trim Word 18 End of Message Word 17 Sub TrimSystem Command RC5 Word Home Theater HEX DEC Standard RC-5 Commands for Home Theater StandardRC-5 Commands for the Home Theater Standard Audio Decode Mode Code
Related manuals
Manual 8 pages 37.25 Kb

RC-5, RS-232 specifications

Krell Industries, renowned for its high-end audio and video components, has made significant advancements in connectivity protocols, particularly the RS-232 and RC-5 interfaces. These technologies are integral to modern home theater systems and high-fidelity audio setups, enabling seamless communication between devices while ensuring superior performance.

The RS-232 interface, a standard for serial communication, is widely used in professional and consumer electronics. Krell’s implementation of RS-232 allows for robust control of audio and video equipment. It supports bidirectional data transmission, which means that not only can commands be sent to the device, but status can also be communicated back to the controller. This feature is essential for integrated systems where centralized control is desired, enhancing user convenience.

One of the standout characteristics of Krell's RS-232 integration is its compatibility with a variety of control systems, including automation interfaces from major brands. This ensures that users can easily incorporate Krell products into their existing setups without compatibility issues. Additionally, the RS-232 connection supports long cable runs, making it ideal for larger installations, such as those in dedicated home theaters or commercial spaces.

On the other hand, the RC-5 protocol, developed by Philips, is a widely adopted infrared standard that facilitates remote control operations. Krell Industries has embraced this technology to ensure that their equipment is easily controllable using standard remote controls or universal remote systems. RC-5’s simplicity and efficiency in sending commands over infrared make it an excellent choice for consumer applications where ease of use is a priority.

One of the main features of the RC-5 system is its command structure, which allows for a variety of user-defined commands. This flexibility enhances user experience, as it enables customization of device response and control sequences. Moreover, Krell’s products designed with RC-5 support can be effortlessly integrated with home automation systems, allowing users to manage their audio and video components alongside lighting, security, and other connected devices.

In summary, Krell Industries’ incorporation of RS-232 and RC-5 interfaces showcases their commitment to quality and user experience in high-end audio and video products. These technologies facilitate seamless integration, robust control, and customization, making the overall system more versatile and user-friendly. With Krell’s innovative approach, enthusiasts can elevate their audio and video experiences to new heights while enjoying the benefits of modern connectivity solutions.