ELECTRICAL INSTALLATION INSTRUCTIONS

All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.

WARNING:

When using electrical products, basic precautions should always be observed, including the following:

1.DANGER: RISK OF ELECTRIC SHOCK

Connect only to a circuit protected by a ground-fault circuit interrupter.

2.Grounding is required. The unit should be installed by a licensed electrician and grounded.

3.Install to permit access for servicing.

4.All building materials and wiring should be routed away from the pump body and heater (if equipped).

The whirlpool should be installed on a 120 vac, 15 amp dedicated circuit. The circuit should be hard-wired from the electrical power supply panel. The circuit must be a three (3) wire circuit from the electrical supply panel. A grounded neutral wire and a third wire, earth ground, are essential.

ELECTRICAL INSTALLATION

SEPARATE 15 AMP GFCI

FOR 1.1HP MODELS

 

120 VAC

 

WHIRLPOOL MOUNTED

 

AIR SWITCH

 

or

 

WALL TIMER

WHITE

BLACK

 

PUMP/MOTOR

 

GND.

ELECTRICAL DIAGRAM

READ AND FOLLOW ALL INSTRUCTIONS

753571-100

(3)

Image 3
Contents List of Required Tools and Supplies General Installation InformationImportant Water test unit before installation and enclosure List of Required Components not includedSuggested Installation Method Typical InstallationFraming and Installation Whirlpool Mounted Electrical Diagram Read and Follow ALL InstructionsAIR Switch Wall TimerHarsh Chemicals should Never be Used on Acrylic Surfaces Wire Selection GuidePost Installation CLEAN-UP Drain Connection and System Test