GE UltraSport manual WW1

Page 7

e

UltraSportTM Floodlight

B e a m Efficiency =53%

Total Efficiency =86%

S01

Beam Efficiency =54%

Total Efficiency =85%

M01

Beam Efficiency =65%

Total Efficiency =84%

W01

Beam Efficiency =70%

Total Efficiency =84%

WW1

Photometric Performance—Traditional sports lighting systems use metal halide lamps with large bulb jackets and mogul base sockets located in the axial center-line of the optical. This lamp design impedes optical efficiency by producing inefficient symmetrical light distributions with too much light in the upper beam. Some upper beam light is lost in the sky and grandstands or, in the worst case, can be the source of light trespass and glare.

The UltraSport floodlight, on the other hand, utilizes an advanced double-ended metal halide lamp without a bulb jacket and a new unique reflector design.

The elimination of the outer bulb allows placement of the lamp arc into the focal point of shallow parabolic reflector forms needed to build high center beam candle power and provide the highest beam efficiency possible with wide beam distributions.

This new lamp/reflector configuration produces a more efficient, oval light distribution with very tight vertical light control to minimize wasted light and maximize light on the playing field.

Glare/Spill Light Control—The UltraSport floodlight’s precise optical design limits the amount of vertical spill and light pollution without the use of external visor/louver assemblies that increase wind loading and structure costs. Optional internal cutoff skirts are available and provide direct cutoff of the arc tube at 15 degrees above the floodlight’s center aiming point for optimum glare control without the high losses normally associated with external glare reducing devices.

Photometric Choices—Different combinations of primary and secondary reflectors, in conjunction with the new double-ended lamp, provide multiple oval light distributions.

S01 =Stadium oval without internal glare control (NEMA 4X2)

S02 =Stadium oval with internal glare control (NEMA 4X2)

M01 =Medium oval without integral internal glare control (NEMA 4X2 [64x24])

M02 =Medium oval with integral internal glare control (NEMA 4X2 [70X24])

W01 =Wide oval without integral internal glare control (NEMA 5X3 [81X38])

W02 =Wide oval with integral internal glare control (NEMA 5X3 [81X37])

WW1 =Extra wide oval without internal glare control (NEMA 5X4)

WW2 =Extra wide oval with internal glare control (NEMA 5X4)

7

Image 7
Contents UltraSport TMFloodlight GE is . . . Sports Lighting What Does the UltraSport Floodlight System Mean to What Is UltraSportTM?Applications System Features Luminaires.5 Technical Description WW1 MOL 2000 208 11.2 2125 10.0 25C 240 2115 Max 277 Structural Data EaseofInstallation/MaintenanceM02 Dimensional Data and Ordering InformationUltraSportTMFloodlight