Bryant 355M-40-5 manuals
Household Appliance > Furnace
When we buy new device such as Bryant 355M-40-5 we often through away most of the documentation but the warranty.
Very often issues with Bryant 355M-40-5 begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Furnace Bryant 355M-40-5 is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Furnace on our side using links below.
Bryant 355M-40-5 Operating Instructions
44 pages 608.02 Kb
installation, start-up, and operating instructionsDELUXE 4-WAY MULTIPOISE VARIABLE-CAPACITY DIRECT-VENT CONDENSING GAS FURNACE 355MAV Series D2 Fig. 2Dimensional DrawingDIMENSIONS (IN.)For airflow requirements above 1800 CFM, use both side inlets, a 4. 3. 2. 1. NOTES: Minimum return-air opening at furnace:*These dimensions reflect the wider casing for the Trophy (96.6 percent AFUE) furnace. 060100 21 19-3/8 19-1/2 060080 21 19-3/8 19-1/2 042080 21 19-3/8 19-1/2 042060 17-1/2 15-7/8 16 042040* 24-1/2* 22-7/8* 23* UNIT SIZE A D E 060120 24-1/2 22-7/8 23 combination of 1 side inlet and the bottom, or the bottom only. MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION 3 **1" 3014 TABLE 1OPENING DIMENSIONS (IN.)Fig. 13Floor and Plenum Opening Dimensions Fig. 14Furnace, Plenum, and Subbase Installed on a Combustible Floor Fig. 15Furnace, Plenum, and Coil Assembly or Coil Box Installed on a Combustible Floor 19 Fig. 24Wiring Diagram 90 225 180 135 LEGEND SCHEMATIC DIAGRAM (NATURAL GAS & PROPANE)10.Ignition-lockout will occur after four consecutive unsuccessful trials-for-ignition. 9. Blower-off delay, gas heating 90, 135, 180 or 225 seconds, cooling or heat pump 90 seconds. 7. Inductor used on all 060 or -20 airflow units. 6. Replace only with a 3 AMP fuse. 4. Symbols are electrical representation only. 3. This wire must be connected to furnace sheet metal for control to prove flame. 2. Use only copper wire between the disconnect switch and the furnace junction box (JB). 1. If any of the original equipment wire is replaced use wire rated for 105C. NOTES: 322296-101 REV. BControl will auto-reset after three hours. 11.Factory connected when LGPS not used. 24 TABLE 6MAXIMUM ALLOWABLE PIPE LENGTH (FT)25 TABLE 6MAXIMUM ALLOWABLE PIPE LENGTH (FT) Continued27 Fig. 34Sidewall Termination of 12 in. or MoreFig. 31Roof Termination (Preferred) Fig. 32Concentric Vent and Combustion-Air Roof Termination (Preferred) Fig. 35Sidewall Termination of Less than 12 in. Fig. 33Concentric Vent and Combustion-Air Side Termination 35 1OFF 44 SERVICE TRAINING
Also you can find more Bryant manuals or manuals for other Household Appliance.