Greenheck Fan 474750 manuals
Power Tools > Stud Sensor
When we buy new device such as Greenheck Fan 474750 we often through away most of the documentation but the warranty.
Very often issues with Greenheck Fan 474750 begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Stud Sensor Greenheck Fan 474750 is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Stud Sensor on our side using links below.
Greenheck Fan 474750 Specifications
8 pages 699.03 Kb
Installation, Operation and Maintenance ManualPart #474750 Digital Temperature InterlockGeneral DescriptionDescription Purpose Product Application Performance Goals Product SpecicationDigital Temperature Interlock 2 Table of ContentsReceiving and HandlingStorage3Digital Temperature Interlock Duct Collar MountingResistive temperature detector(s) may be factory installed. If so, continue to the next section. Resistive Temperature Detector(s) (RTD) Mounting 3 InstallationControl Box MountingLocate an area with enough space to mount the control box and fasten to the wall. All eld installation and wiring of electrical equipment must be done to meet NEC and local codes. Control box may be factory mounted. If so, continue to the next section. CAD Drawing from Tyler Schilling Emailed to Barb on March 22, 2011Octagon Extension PN 830125 Lock Washer Nut Compression Seal PN 463570 Gasket J-Box Plate PN 732396 Resistive Temperature Detector (RTD) PN 384439 Octagon Cover PN 380926 3 inch air space 2 inch typical 19.525 inches Octagon Extension PN 830125 0.75 to 0.875 inch (19.0 to 22.2 mm) diameter hole Hood Surface Sensor Install (cutout area) Exhaust Area Supply Area (optional) HOOD PLAN VIEW MROCZENSKI_L 12/02/2009 1/4 IAN29890 INSTR, ADJ. TEMP INTERLOCK IN FLAT SPOT Calibration 4 Electrical ConnectionsElectrical Connections Breaker Panel to Control Box or Fan Control Center Circuit Connections 5 Control Circuit Diagram (Standard Control)UL LISTED WIRING FOR ADDITIONAL SENSORS (OPTIONAL) ADJUSTABLE TEMPERATURE INTERLOCK WIRING 6 Control Circuit Diagram (Fan Control Center)FS2 BR - brown WIRE COLOR PR - purple RD - red FILE #E200616 TORQUE:LABEL DESCRIPTION PB Push Button KFCC-TEMP-INTERLOCKwith re system armed (non-re mode). (in normal operation, R1 & R2 are energized) UNDER SUBJECT 891 Fan Switch95 A2 95 A2 2 7 R2 (can be used for shunt trip, alarms, etc.) open w/power at H1/N1 & re sys. armed closed w/power at H1/N1 & re sys. armed Spare Relay Contacts closed on re or no power open on re or no power 4 3 R2 1 5 8 6 (activated by FS1) 96 A1 Lights SwitchKFCC HD-1 F1 EF-1 1.5 460 3 3.0 14ga 15amp F2 MAU-1 1.0 460 3 2.8 14ga 15amp CONTROL PANELC NO FS1 T1 NOC T1 T2 TC1VoltSpare Fire Switch Contact (dry contacts for building alarm) STB Shunt Trip Breaker If wall mounted prewire, or eld installed re system, the re system microswitches must Drawing shown de-energized at L1 (term.#H1), AF Air Flow Switch be eld wired. UL LISTEDD Damper EC Evap Cooler TC Temperature Controller SV Gas Solenoid NOTES: ST Starter S Switch LT Light G Ground FS Fire Switch EF Exhaust Fan SF Supply Fan OL OverLoad C Contactor R Relay NC NO Hood Mark(s): Fan MarkMotor HP Panel Mark:OR - orange YW - yellow WT - white BK - black BL - blue FIELD WIRING: 7 OperationTesting Troubleshooting MaintenanceDaily Weekly Seasonal Whom to call What to have ready for the call 8 WarrantyFrequently Asked Questions Replacement Parts Codes and Standards Compliance
Also you can find more Greenheck Fan manuals or manuals for other Power Tools.