NEC 120 manuals
Cell Phone > Cell Phone
When we buy new device such as NEC 120 we often through away most of the documentation but the warranty.
Very often issues with NEC 120 begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Cell Phone NEC 120 is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Cell Phone on our side using links below.
46 pages 459.86 Kb
125 pages 1.22 Mb
3 NEAX7400 ICS Model 120 Installation Procedure Manual Revision Sheet 1/3 AD-251825014 NEAX7400 ICS Model 120 Installation Procedure Manual Revision Sheet 2/3 AD-251825015 NEAX7400 ICS Model 120 Installation Procedure Manual Revision Sheet 3/3 AD-251825016 IMPORTANT SAFETY CONSIDERATIONS9 NEAX7400 ICS Model 120 Installation Procedure Manual15 CHAPTER 1 INTRODUCTIONAD-25182501 CHAPTER 2 Page 3 17 CHAPTER 2 GENERAL INFORMATION1. TRUNKING DIAGRAM A typical trunking diagram for the PABX is shown in Figure 2-1. Figure 2-1 PABX Trunking Diagram Note 1: Figure 2-6: 4-PIM Configuration for 19-Inch Rack-Mounting InstallationAD-25182501 CHAPTER 2 Page 9 PIM3 PIM2 PIM1 23 Front View Rear View24 CHAPTER 3 INSTALLATION PROCEDUREFigure 3-2 Static Electricity Guard (Continued) 26 29 ATTENTION36 NotePage 27 41 Sheet 9/29Figure 003-9 Screwing the RACK PARTS to a Wall 43 Sheet 11/29Figure 003-12 Modular Layout for 2 PIM Configuration Figure 003-11 Modular Layout for 1 PIM Configuration10 Pair MDF0 or TPF0 LTC1 LTC2 100 Pair (L) SHELF 1 MIN. BACKUP, 26 A-H SHELF 2 MED. BACKUP, 52 A-H - Page 30 44 Sheet 12/29Figure 003-13 Modular Layout for 3 PIM Configuration 45 Sheet 13/29Figure 003-14 Modular Layout for 4 PIM Configuration 46 Sheet 14/29PS12260 (for PIM's 0 to 3). add only one more BATTM - If a 78 A-H Battery is requried, (1 ONLY). required use dummy module - If BATTM0 or BATTM1 is not backup configuration. backup either as MIN. or MED. be supplied for external battery - BATTM0 and/or BATTM1 can powerboard. - 240V connect to 4 way (R) Krone (MDF 2). - LTC 1-2 connect to (L) Krone (MDF 2) - PIM 5 - LTC 0 connect to PIM 4 and 5 = 2.5 m PIM's 0 to 3 = 1.5 m Notes: - MDF cable lengths: Figure 003-15 Modular Layout for 5 PIM Configuration 47 Sheet 15/2952 A-H (SHELF 1+2), - more BATTM (for PIM's 0 to 3). - If 78 A-H Battery is requried, add only one dummy module (1 ONLY). - If BATTM0 or BATTM1 is not required use backup configuration. external battery backup either as MIN. or MED. - BATTM0 and/or BATTM1 can be supplied for - 240V connects as shown. - PIM 4 - LTC 0-2 connect to (L) Krone (MDF 2). PIM 4 = 2.5 m PIM's 0 to 3 = 1.5 m Notes: - MDF cable lengths: Figure 003-16 Modular Layout for 6 PIM ConfigurationPS12260 SHELF 1 MIN. BACKUP, 26 A-H SHELF 2 MED. BACKUP - Page 34 48 Sheet 16/29PS12260 (for PIM's 0 to 3). add only one more BATTM - If a 78 A-H Battery is requried, (1 ONLY). required use dummy module - If BATTM0 or BATTM1 is not backup configuration. backup either as MIN. or MED. be supplied for external battery - BATTM0 and/or BATTM1 can powerboard. - 240V connect to 4 way (R) Krone (MDF 2). - LTC 1-2 connect to (L) Krone (MDF 2) - PIM 5 - LTC 0 connect to PIM 4 and 5 = 2.5 m PIM's 0 to 3 = 1.5 m Notes: - MDF cable lengths: Figure 003-17 Modular Layout for 7 PIM Configuration 49 Sheet 17/29PS12260 other for PIM's 4 to 6). BATTM (one shelf for PIM's 0 to 3 and the - If a 78 A-H Battery is requried, add one more dummy module (1 ONLY). - If BATTM0 or BATTM1 is not required use or MED. backup configuration. for external battery backup either as MIN. - BATTM0 and/or BATTM1 can be supplied - 240V connect to 4 way powerboard. - LTC 2 connect to (L) Krone (MDF 3). - PIM 6 - LTC 0-1 connect to (R) Krone (MDF 2) PIM's 4 to 6 = 2.5 m Notes: - MDF cable lengths: PIM's 0 to 3 = 1.5 m Figure 003-18 Modular Layout for 8 PIM Configuration- AD-25182501 CHAPTER 3 Page 37 51 Sheet 19/29Figure 003-19 1 PIM Configuration (19Rack Mount) 52 Sheet 20/29Figure 003-20 2 PIM Configuration (19Rack Mount) 53 Sheet 21/29Figure 003-21 3 PIM Configuration (19Rack Mount) 54 Sheet 22/29Figure 003-22 4 PIM Configuration (19Rack Mount) 56 *Page 45 59 Sheet 27/29Figure 003-27 Mounting of the BUS Cards 61 Sheet 29/29Figure 003-29 Connection of the BUS Cables 64 (a) ATI CA-AFigure 004-3: ATT Cable Connection to Main Equipment4 : CHAMP CONNECTOR 2 : HOUSING CONNECTOR 1 : ATT CONNECTOR (J) 3 : CHAMP CONNECTOR ~~ INSTALLATION CABLE (MAX. 296m) SN694 ATTCON PN-CS00 ATT PABX PIM0 ATI CA-A 4m 1 23 4 Page 51 65 NAP- 200-004 Sheet 4/9 Installation of Peripheral EquipmentFigure 004-3: ATT Cable Connection to Main Equipment (Continued)2 : CHAMP CONNECTOR 1 : CHAMP CONNECTOR 3 : CHAMP CONNECTOR 4 : ATT ~~ Note 1:The total length of the installation cable plus ATI CA-A must be maximum 300 m. (b) INSTALLATION CABLEINSTALLATION CABLE MAX. 296m (WITH 0.5 DIAM. CABLE) SN694 ATTCON ATI CA-A 1 23 4 Note Page 59 73 Figure 005-4: Internal Battery Connection for 8 PIMs Configuration74 CAUTION: vented ONLYPage 65 79 Sheet 2/42Figure 007-2: Location of LENAD-25182501 CHAPTER 3 Page 66 80 Sheet 3/42(b) LEN 0256 ~ 0511 Figure 007-2: Location of LEN (Continued) 81 Sheet 4/42(3) Figure 007-3 shows the LTC Connector Pin Arrangement. (a) PIM0 (LTC0 ~ LTC2) Figure 007-3: LTC Connector Pin ArrangementAD-25182501 CHAPTER 3 Page 68 82 Sheet 5/42(b) PIM1 (LTC0 ~ LTC2) 83 Sheet 6/42(c) PIM2 (LTC0 ~ LTC2) 84 Sheet 7/42(d) PIM3 (LTC0 ~ LTC2) 85 Sheet 8/42(e) PIM4 (LTC0 ~ LTC2) 86 Sheet 9/42(f) PIM5 (LTC0 ~ LTC2) 87 Sheet 10/42(g) PIM6 (LTC0 ~ LTC2) Figure 007-3: LTC Connector Pin Arrangement (Continued) 88 Sheet 11/42(h) PIM7 (LTC0 ~ LTC2) 93 Sheet 16/42(1) C.O./D.I.D. Trunks (a) 4 Line C.O. Trunks (PN-4COTE and PN-4DITB). Figure 007-4: MDF Cross Connection for 4 Line C.O. Trunk (PN-4COTE)26T01R0 27T12R1 28T23R2 29T34R3 Page 80 94 Sheet 17/42(b) 2 Line C.O. Trunk (PN-2COTD) Figure 007-5: MDF Cross Connection for 2 Line C.O. Trunk (PN-2COTD) 95 Sheet 18/42(2) Tie Line Trunk (a) 4W E&M Trunk (PN-2ODTA) Figure 007-6 MDF Cross Connection for a 4W E&M Trunk Card (PN-2ODTA) 96 Sheet 19/42Figure 007-6 MDF Cross Connection for a 4W E&M Trunk Card (PN-2ODTA) (Continued) 97 Sheet 20/42(b) LD Trunk (PN-2LDTA) Figure 007-7: MDF Cross Connection for an LD Trunk (PN-2LDTA) 98 Sheet 21/42(3) 2 Line DID Trunk (PN-AUCA) Figure 007-8 MDF Cross Connection for a DID Trunk Card (PN-AUCA) Page 85 99 Sheet 22/42(4) Single Line Telephone (SLT) (a) Standard Line (PN-4LCE/4LCF) Figure 007-9 MDF Cross Connection for a Single Line Telephone (Standard Line) 100 Sheet 23/42(b) Long Line (PN-AUCA) Figure 007-10 MDF Cross Connection for a Single Line Telephone (Long Line) Page 87 101 Sheet 24/42(5) Dterm /DSS Console (a) Standard Line (PN-4DLCA) Note: Applies only to Dterm 65 series. * The colours shown are the most common. In any case, use only the inner pair of connector. Figure 007-11 MDF Cross Connection for a Dterm/DSS Console (Standard Line) 102 Sheet 25/42(b) Long Line (PN-2DLCB) Note: Applies only to Dterm 65 series. * The colours shown are the most common. In any case, use only the inner pair of connector. Figure 007-12 MDF Cross Connection for a Dterm/DSS Console (Long Line) 103 Sheet 26/42(6) SN611 ATTCON and Dterm 6D/16D series telephones. * The colours shown are the most common. In any case, use only the inner and outer pairs as shown. Figure 007-13 MDF Cross Connection for an SN611 ATTCON and Dterm 6D/16D. 104 Sheet 27/42GND Figure 007-14 MDF Cross Connection for Day/Night Mode Change by External Key Sheet 29/42 106 Figure 007-16 MDF Cross Connection for a TAS Indicator with a Battery 107 Sheet 30/42Figure 007-17 MDF Cross Connection for a TAS Indicator without a Battery 108 }Page 95 109 Sheet 32/42Figure 007-19 MDF Cross Connection for Paging EquipmentAUSTEL - approved Line Isolation Unit Page 96 110 Sheet 33/42Figure 007-19 MDF Cross Connection for Paging Equipment (Continued) 111 }Page 98 112 Sheet 35/42Figure 007-21 MDF Cross Connection for External Music EquipmentAUSTEL - approved Line Isolation Unit Page 99 113 Sheet 36/42Figure 007-21 MDF Cross Connection for External Music Equipment (Continued) 115 Sheet 38/42Page 103 117 Sheet 40/42Figure 007-25 MDF Cross Connection for the PFT 118 Sheet 41/42Page 106 CAUTION: Figure 008-1: Lamp Indication on PZ-PW86(A) Card 120 _ ++ _Set the appropriate voltage before tu rning on the AC switch.
78 pages 5.19 Mb
Also you can find more NEC manuals or manuals for other Cell Phone.