State Industries SUF 100 THRU 250 manuals
Household Appliance > Water Heater
When we buy new device such as State Industries SUF 100 THRU 250 we often through away most of the documentation but the warranty.
Very often issues with State Industries SUF 100 THRU 250 begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Water Heater State Industries SUF 100 THRU 250 is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Water Heater on our side using links below.
State Industries SUF 100 THRU 250 Manual
49 pages 8.47 Mb
3 TABLE OF CONTENTS4 INTRODUCTIONQUALIFICATIONS 5 TOOLS REQUIRED6 GENERAL INFORMATIONINSTALLATION REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS GAS PRESSURE SPECIFICATIONS 7 INSTALLATION QUICK TIPS SUF 120 AND 150 GAS PRESSUREADJUSTMENT PROCEDURE: GAS PRESSURE SUF 120 AND 150 MODELS HIGH ALTITUDE INSTALLATIONS SUF 120 150 9 INSTALLATION QUICK TIPS SUF 199 AND 250 GAS PRESSUREADJUSTMENT PROCEDURE: GAS PRESSURE SUF 199 AND 250 MODELS HIGH ALTITUDE INSTALLATION GAS ORIFICE 10 INSTALLATION QUICK TIPS SUF 300, 400, 500 GAS PRESSUREADJUSTMENT PROCEDURE: GAS PRESSURE SUF 300, 400, 500 HIGH ALTITUDE ADJUSTMENT SUF 300, 400, 500 12 INSTALLATION VENTING CATEGORY AND MATERIALS13 VENTING TABLES SUF 120 250VENTING TABLES SUF 300, 400, 500 14 CONCENTRIC VENTING15 VENT CONDENSATION14 Servicing should only be performed by a Qualied Service Agent E BK J AVENT TERMINAL AIR SUPPLY INLETAREA WHERE TERMINAL IS NOT PERMITTED 16 V Xv vG CBB F H M D L POWER VENT(using room air for combustion) EXTERIOR CLEARANCES FOR SIDEWALL VENT TERMINATION D C I B A E F G VENT TERMINAL AIR SUPPLY INLETAREA WHERE TERMINAL IS NOT PERMITTED 17 V Xv vB E D L DIRECT VENT(using outdoor air for combustion) EXTERIOR CLEARANCES FOR SIDEWALL VENT TERMINATION D C A B I E F G 18 VENT TERMINATION DIRECT VENT ALL MODELS19 DIRECT VENTING ALL MODELS20 CONTROL OVERVIEW22 ADJUSTING TANK TEMPERATURE OPERATING SET POINT DIFFERENTIAL24 CHANGING THE DISPLAY UNITS26 FAULT AND WARNING CONDITIONS ADVANCED DIAGNOSTIC INFORMATION27 ACCESS TO THE CURRENT FAULT OR WARNING28 FAULT CODES29 VIEWING THE FAULT HISTORY VIEWING INFORMATION ABOUT THE HEATER30 CONTROL SEQUENCE (TYPICAL ALL MODELS)32 CONTROLS CENTRAL CONTROL BOARD CCB36 CONTROLS GAS VALVE SUF 199 AND 25037 CONTROLS GAS VALVE, ORIFICE CHART SUF 300/40038 CONTROLS GAS VALVE, ORIFICE CHART SUF 50039 CONTROLS PRESSURE SWITCHES ALL MODELS42 CONTROLS CONNECTIONS, IGNITER, FLAME SENSOR, SIGHT GLASS, POWERED ANODES43 HOT SURFACE IGNITER / FLAME SENSOR / CONTROL TIMING44 BLOWER SPEED CONTROL SUF 199 AND 25045 VARIABLE FREQUENCY DRIVE SUF 400 AND 50046 VARIABLE FREQUENCY DRIVE BLOWER SPEED AND PRESSURE READINGS47 WIRING DIAGRAM SUF 120 300B (CENTRAL CONTROL BOARD)CC N L50VA 6J5J4J7J51J 61J IU MUSER INTERFACE MODULE01J31J2J3J1JTRANSFORMER INSIDE CCB ENCLOSURE GROUND STRIP BURNER GROUND (BURNER BOLT) ON/OFF SWITCH GROUND 120 VAC NEUTRAL 120 VAC HOT NOITCNUJ XOBENABLE/DISABLE CIRCUIT JUMPER WIRE BETWEEN PINS 8 AND 11 ON J6 PLUG 46 Servicing should only be performed by a Qualied Service Agent 48 WIRING DIAGRAM SUF 400, 500LOWER TEMPERATURE PROBE COMBUSTION BLOWER N LNOTE: COMBUSTION BLOWER MOTORS ON 400,000 & 500,000 Btu/hr MODELS ARE THREE PHASE (3) MOTORS. BLOCKED INTAKE AIR USER INTERFACE MODULE MIUBCCBLOCKED EXHAUST BLOWER PROVER 24 VAC GAS VALVE 6J5J4J7J51J 61J 01J31J2J3J1JTRANSFORMER 50VA GROUND STRIP BURNER GROUND (BURNER BOLT)LOW GAS PRESSURE SWITCH ANODE 1 ANODE 2 NOITCNUJ XOBUPPER TEMPERATURE PROBE HOT SURFACE IGNITER FLAME SENSOR (CENTRAL CONTROL BOARD)INSIDE CCB ENCLOSURE GROUND 120 VAC NEUTRAL 120 VAC HOTENABLE/DISABLE CIRCUIT JUMPER WIRE BETWEEN PINS 8 AND 11 ON J6 PLUG VFDVARIABLE FREQUENCY DRIVE ON/OFF SWITCH
Also you can find more State Industries manuals or manuals for other Household Appliance.