Troubleshooting

Problem

 

Possible Causes

 

Likely Solutions

Pressure Washer

1. Cord not connected.

1.

Check that cord is plugged in.

will not start

2.

No power at outlet.

2.

Check power at outlet. If outlet is unpowered,

 

 

 

 

turn off tool and check circuit breaker.

 

 

 

 

If breaker is tripped, make sure circuit is right

 

 

 

 

capacity for tool and circuit has no other loads.

 

3.

GFCI circuit breaker tripped.

3.

Press reset button on GFCI unit on cord.

 

4.

Internal damage or wear.

4.

Have a qualified technician service tool.

 

 

(Carbon brushes or switch, for example.)

 

 

Pressure Washer

1. GFCI circuit breaker tripped.

1.

Press reset button on GFCI unit on cord.

stops suddenly

2. Water leaking from housing.

2.

SHOCK HAZARD! IMMEDIATELY

 

 

 

 

discontinue use. Have the unit repaired by

 

 

 

 

a qualified technician before further use.

Output pressure

1. Not enough water supply.

1.

Check water supply hose for kinks, leaks,

varies

 

 

 

or blockage. Open faucet all the way.

 

2.

Air in water supply.

2.

Check that all connections are tight.

 

3.

Water Inlet Filter is clogged.

3.

Remove Filter and clean.

 

4.

Extension Nozzle not

4.

Pressure is created by the Nozzle, not the

 

 

attached to Spray Gun.

 

Spray Gun. Attach Extension Nozzle to unit.

 

5.

Nozzle is clogged.

5.

Remove Nozzle and clean.

 

6.

Nozzle has mineral build up.

6.

Remove Nozzle and clean with vinegar.

 

7.

Garden hose is too long.

7.

Recommended garden hose length is

 

 

 

 

20 to 50 feet, or 30 feet if using well water.

 

 

 

 

Shorten the length of the garden hose

 

 

 

 

if needed to increase pressure.

 

8.

Internal valves or seals may

8.

Have a qualified technician service tool.

 

 

be worn or sticking.

 

 

Trigger does

Safety lock is still engaged.

Press in on the release button on the bottom of

not depress

 

 

the Spray Gun Handle to release the Safety Lock.

Detergent will

Incorrect detergent type.

Check that the detergent is the recommended

not dispense

 

 

type of detergent. Clean out dispenser and

 

 

 

replace with correct type if needed.

Performance

Clogged with mineral deposits.

Clean unit with a de-mineralizing solution such

decreases over time

 

 

as vinegar or other aqueous acidic cleaner.

Follow all safety precautions whenever diagnosing or servicing the tool. Disconnect power supply before service.

Safety

Setup