2-2 CHAPTER 2: INSTALLATION AND SETUP
Water or moisture cannot enter the case of the unit.
Temperature must be within the range of 0 to 40 degrees Celsius.
Air-flow around the unit and through the vents in the side of the
case is not restricted. You should provide a minimum of 25mm
(1-inch) clearance.
No objects are placed on top of the unit.
Units are not stacked more than four high if the Switch is
free-standing.
Configuration Rules
for Ethernet The connectors, supported media types, and maximum distances for
the Switch 3800 are described in Chapter 1.
Installing the
Switch 3800 The Switch 3800 can be mounted in a rack, or placed free-standing on
a tabletop.
Rack Mounting The Switch 3800 is 2U high and will fit in most standard 19-inch racks.
CAUTION: The Switch should only be used in a rack if it is mounted on
runners, a shelf, or a tray to support the weight. The rack mount kits
alone are not sufficient to support the weight of the Switch. The rack
mount kits must not be used to suspend the Switch from under a table
or desk, or attach it to a wall.
To install the mounting brackets on the Switch, follow these steps:
1Place the Switch the right way up on a hard flat surface, with the front
facing toward you.
2Remove the existing screws from the sides of the chassis.
3Locate a mounting bracket over the mounting holes on one side of the
unit.
4Insert the four screws and fully tighten with a suitable screwdriver, as
shown in Figure 2-1.
SW3800.BK Page 2 Tuesday, May 5, 1998 5:20 PM