24 CHAPTER 2: INSTALLING THE SWITCH
Choosing a Suitable Site
The Switch is suited for use in an office environment where it can be
mounted in a standard 19-inch equipmen t rack, or free standing.
Alternatively, the Switch can be rack-mounted in a wiring closet or
equipment room. A rack-mounting k it, containing two mounting
brackets and six screws, is supplied with the Switch.
When deciding where to position the Switch, ensure that:
You are able to meet the configuration rules detailed in
Configuration Rules for Fast Ethernet on page 20.
The Switch is accessible and cables can be connected easily.
Cabling is away from:
Sources of electrical noise such as radios, transmitters and
broadband amplifiers
Power lines and fluorescent lighting fixtures
Water or moisture c annot enter the cas e of the Switch.
Air-flow is not restricted around the Switch o r through the vents in the
side of the Switch. We recommend that yo u provide a minimum of
25mm (1in.) clearance.
No more than four Switch units are placed o n top of one another, if
the units are free standing.
Rack-mounting The Switch is 1.5U high and fits in most standard 19-inch racks.
CAUTION: Disconnect all cables from the Switch b efore continuing.
Remove all self adhesive pads from the underside of the Switch if they
have been fitted.
1Place the Switch the right way up on a hard flat surface, with the front
facing towards y ou.
2Locate a mounting bracket over th e mounting holes on one side of the
Switch, as shown in Figure 7.
16950ua.bk Page 24 Thursday, April 29, 1999 1:28 P M