Appendix C — Troubleshooting
C-4 Ethernet Power Supply User s Guide
Problem Resolution
The end device
operates, but
there is no data
link.
Verify that:
The Port LED on the Ethernet Power
Supply front panel is lit continuously.
The "Data" and "Data & Power" ports
correspond.
If an external splitter is in use, replace
it with a new splitter. Discard the
faulty splitter.
You are using a standard UTP
Category 5 cable, including all 8 wires
(4 pairs), and is 100m or less in
length between the switch and the
end device.
You are not using any crossover
twisted pair wires.
The Ethernet Power Supply is
connected to a switch or hub with a
good RJ-45 patch cord connection.
In addition, try to:
Bypass the long twisted pair cable
and bring the end device close to the
Ethernet Power Supply and connect
to one of the ports using a short
cable. If this works, there is probably
a faulty connection or short on the
long cable, or one bad RJ-45
connection along the line.