Canada

This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications, ICES-003.

Le présent appareil numérique n'émet pas de bruits radioélectrique dépassant les limits applicables aux appareils numériques de la classe B prescrites dans le Réglement sur le brouillage radioélectrique édicté par le ministere des Communications du Canada, NMB-003.

European Union

Xerox Corporation declares, under our sole responsibility, that the printer to which this declaration relates is in conformity with the following standards and other normative documents:

Following the provisions of the Low Voltage Directive 73/23/EEC and its amendments:

EN 60950 (IEC 60950) "Safety of Information Technology Equipment including Electrical Business Equipment"

Following the provisions of the Electromagnetic Compatibility Directive 89/336/EEC and its amendments:

EN 55022:1998

"Limits and Methods of measurement of radio interference characteristics

(CISPR 22)

of Information Technology Equipment." Class B.

 

 

 

 

 

EN 61000-3-2:1995

"Part 3: Limits - Section 2: Limits for harmonic current emissions

+A1:1998+A2:1998

(equipment input current less than or equal to 16A per phase)."

 

 

 

(IEC61000-3-2)

 

 

 

 

 

EN 61000-3-3:1995

"Part 3: Limits - Section 3: Limitation of voltage fluctuations and flicker in

(IEC61000-3-3)

low-voltage supply systems for equipment with rated current less than or

equal to 16A."

 

 

 

 

 

EN 55024:1998

"Information technology equipment - Immunity characteristics - Limits and

(CISPR 24)

methods of measurement."

 

 

 

 

 

 

 

 

 

 

CISPR 24 Immunity Phenomena

Basic Standard

Test Specification

 

 

 

 

Electrostatic Discharge

 

IEC 61000-4-2:1995

6 kV Contact, 10 kV Air

 

 

 

Radio-Frequency Electromagnetic

IEC 61000-4-3:1995

80-1000 MHz, 3 V/m, 80% AM

Field (radiated)

 

 

@ 1 KHz

 

 

 

 

Fast Burst Transients

 

IEC 61000-4-4:1995

5/50 Tr/Th ns, 5 kHz Rep. Freq

 

 

 

0.5 kV Signal Lines

 

 

 

1 kV AC Mains

 

 

 

 

Line Surge

 

IEC 61000-4-5:1995

Combination wave

 

 

 

2.0 kV Common mode

 

 

 

2.0 kV Differential mode

 

 

 

Radio-Frequency Electromagnetic

IEC 61000-4-6:1996

0.15 - 80 MHz, 3 V, 80% AM @ 1 kHz

Field (Conducted)

 

 

 

 

 

 

 

Impressora a laser Phaser™ 4500

D-2

Page 2
Image 2
3Com 4500 manual Canada, European Union