Transmitter Set Up:
Direct Connect Method
Induction Method
Transmitter Operation:
Ground
Suspected
Cable Path
Note: Never connect ground to water pipe or other services in the area. The return signal may mislead the trace.
Transmitter
Hinge
| ||
Suspected | ||
Ground | Cable Path | Ground |
DynatelTM | 577Hz 33KHz |
Off | Hz |
|
tynuCont | Freq | Output Level |
On
nsm n n
SIGNAL
Remove
Ground
Red Clip | Black Clip to |
to Shield | Ground Rod |
| Transmitter |
1.Place the transmitter on the ground over the target cable with the lid hinge in line with the cable path.
1.Hold down for Battery Test (solid tone=good; beeping tone=low; no tone=replace batteries).
2.Press to turn the unit on and select Continuity
DANGER!
Check for stray voltages before attaching transmitter. Voltage greater than 240 volts will damage equipment and cause personal injury and death. Follow standard procedures for reducing the voltage.
1.With the transmitter off, plug the direct connect cable into the transmitter front panel jack.
2.Connect the black clip to the ground rod.
3.Place the ground rod in the earth as far from the near
end connection as the leads will allow, at a 90± degree angle to the suspected cable path.
4.Remove the
Dyna-Coupler Method
(Optional Accessories Required)
Pedestal | Note: The coupler jaws | |
must fully close for signal | ||
To | ||
transmission. | ||
Transmitter |
| |
| ||
Transmitter | Suspected | |
| Cable Path | |
SIGNAL |
|
1.Plug the
accessories). Plug the cable into the transmitter front panel jack.
2.Clamp the
Note:
Test (solid tone=good ground; beeping tone= usable ground; no tone=poor ground or no far end ground). Both LEDs light continuously during the continuity test.
3.Press to apply Tracing Tone and select the
desired frequency: 577 Hz for direct connect with far end ground; or 33 KHz for direct connect with no far end ground, or for use with coupler, or induction.
LED indicates frequency selection. (This key can also turn the unit on.)
4.Press to change output level. Choose Normal output (flashing LED) for locating short to
moderate distances using direct connect method. Use High output (solid LED) for coupler, induction, or direct connect for long distances and deep cables.
5.When locating is complete, press to turn the unit off.