Solvingproblems
ProblemCauseAction
Nopoweratreceptacle.Resetfacilitycircuitbreaker.
Powercorddisconnectedatreceptacle.Plugpowercordintoreceptacle.
Systemfuseopen.Replacefuseintheelectronicsenclosure.
Seefusereplacementprocedure.
Noalarm,nogreenpower
indicatorontheelectronics
enclosure.
Systemfailure.Placeaservicecall.
Processorrequiresreset.T urnthesystemoff,wait5seconds,then
turntheswitchon.
Stripsinbookdesensitizedormissing.Resensitizebooks,orinstallasecuritystrip
inthebook.
Metalobjectstooclosetolattice.Moveallmetaltominimumdistanceof36
inchesfromthelattices.
Noalarm,powerindicatoron.
Systemfailure.Placeaservicecall.
Protectedmaterialfromanotherlibraryora
retailstore.
Identifymaterialthatcausedthealarm.
Failuretodesensitizestripsproperly.Checkdesensitizingprocessandtraining.
Miscellaneousmetallicobjects.Infrequentunwantedalarmsarepossible
fromsomemetalobjects.
Unwantedalarms.
Systemfailure.Placeaservicecall.
Metalobjectstooclosetolattice.Moveallmetaltominimumdistanceof36
inchesfromthelattices.
Electricalinterference.Removepossiblesourcesofelectrical
interferencesuchascomputers,copiers,
TVs,electronicdevices,orenergy
managementsystems.
Incompletewalk-throughtest.Testthesystembywalkingcompletely
throughthecorridor.
Booksnotproperlyresensitized.Resensitizebook,checksensitizingmethod
andstafftraining.
Reducedcoverage,noalarm.
Systemfailure.Placeaservicecall.
Metalobjectstooclosetoalattice.Moveallmetalobjectstoaminimumof36
inchesfromthelattice.
Markedbookorstripstooclosetolattice.Movethemarkedbookstoaminimumof
36inchesfromthelattice.
Electricalinterference.Eliminatesourceofinterference.
Alarmintermittentwithno
trafficincorridor.
Systemfailure.Placeaservicecall.
Copyright©2008.3M.Allrightsreserved.15