1ï
Sensitivity
The programming and sensitivity of the photo detector system (which responds to the light from the welding arc) can be adjusted to accommodate a variety of welding methods and workplace conditions. In order to see the current sensitivity setting, momentarily press the SENS button. To select another setting, press the SENS button repeatedly until the LED shows the desired setting.
Position | Locked in light state (shade 3) at all times |
| Used for grinding |
Position 1 | Least sensitive setting. Used if there is interference |
| from other welders’ arcs in the vicinity. |
Position 2 | Normal position. Used for most types of welding |
| indoors and outdoors. |
Position 3 | Position for welding with low current or with stable |
| welding arcs. (eg TIG welding) |
Position 4 | Suitable for very low current welding, use of inverter- |
| type TIG welding machines. |
Position 5 | Most sensitive setting. Used for TIG welding where |
| part of the arc is obscured from view. |
Position | Locked in selected dark state. Same function as a |
| passive welding filter. |
Position locked light state 









This setting could be used for grinding or other
Position 1-5
If the filter does not darken during welding as desired, increase the sensitivity until the welding filter switches reliably. Should the sensitivity be set too high, the filter may remain in the dark state after welding is complete due to ambient light. In this case, adjust the sensitivity downward to a setting where the welding filter both darkens and lightens as desired.
4