ATTENTION • When the interior portion has become overheated, for safety purposes, the power source is automatically turned off, and the indicator lamps may also be turned off. In such a case, press the “” (power OFF) side of the main power switch, and wait at least 45 minutes. After the unit has sufficiently cooled down, please make confirmation of the attachment state of the lamp and lamp cover, and then turn the power on again.

Lighting and flashing of the power indicator, the lamp indicator, and the temp indicator have the meanings as described in the table below. Please respond in accordance with the instructions within the table. If the same indication is displayed after the treatment, or if an indication other than the following is displayed, please contact your dealer or service company.

power

lamp

temp

Description

indicator

indicator

indicator

 

 

 

 

 

Lighting in

Turned off

Turned off

The unit is in a standby state. Please refer to the “Power

orange

ON/OFF” section of this manual.

 

 

 

 

 

 

Flashing in

Turned off

Turned off

The unit is warming up. Please wait.

green

 

 

 

Lighting in

Turned off

Turned off

The unit is in an ON state. Ordinary operations may be

green

performed.

 

 

 

 

 

 

Flashing in

Turned off

Turned off

The unit is cooling down. Please wait.

orange

 

 

 

 

 

 

The unit is cooling down. A certain error has been detected.

Blinking in

-

-

Wait until the power indicator has finished flashing, and then

red

perform the proper response measure using the item

 

 

 

 

 

descriptions below as reference.

 

 

 

 

 

 

 

The projector lamp has not been properly fixed (attached),

 

 

 

the projector lamp does not light, and/or there is a possibility

 

 

 

that the interior portion has become heated. Turn the power

Lighting or

 

 

OFF and wait at least 20 minutes. After the unit has sufficiently

Lighting in

 

cooled down, please make confirmation of the following items,

blinking in

Turned off

red

and then turn the power ON again. If the same indication is

red

 

displayed, please change the lamp.

 

 

 

 

 

• Is there blockage of the air passage aperture?

 

 

 

• Is the air filter is dirty?

 

 

 

• Does the peripheral temperature exceed 35°C?

 

 

 

 

Lighting or

 

 

The lamp cover has not been properly fixed (attached). Turn

Blinking in

 

the power OFF and wait at least 45 minutes. After the unit has

blinking in

Turned off

sufficiently cooled down, please make confirmation of the

red

red

 

attachment state of the lamp and lamp cover, and then turn

 

 

 

 

 

the power ON again.

 

 

 

 

39

Page 39
Image 39
3M H10 manual Regarding The Indicator Lamps, Power Lamp Temp Description

H10 specifications

The 3M H10 series represents the pinnacle of head protection technology, designed to meet the rigorous demands of various industries while prioritizing user comfort and safety. With a focus on innovative features, the H10 combines advanced materials and engineering to deliver exceptional performance in protective headgear.

One of the standout features of the 3M H10 is its robust construction. Made with high-quality polycarbonate material, the helmet is lightweight yet highly durable, ensuring that it can withstand the rigors of industrial environments. Its impact-resistant design not only protects against falling objects but also enhances user safety during potentially hazardous operations.

The H10 series incorporates 3M’s proprietary Comfort System, which significantly improves wearability. The helmet is fitted with a moisture-wicking liner that actively draws perspiration away from the skin, allowing for extended use without discomfort. The adjustable suspension system provides a customized fit, accommodating various head sizes and promoting stability. This ensures the helmet remains securely in place, increasing protection while allowing for easy movement.

Another important characteristic of the H10 is its versatility. The helmet is compatible with a range of 3M attachment accessories, such as visor mounts, hearing protection, and communication devices, making it suitable for diverse applications, from construction and manufacturing to logging and mining. This adaptability enhances its functionality, offering users an all-in-one solution for head protection and additional safety measures.

In addition to these features, the 3M H10 is designed with ventilation in mind. Thoughtfully placed vents allow for optimal airflow, reducing heat buildup during long periods of wear. This attention to comfort is crucial, especially in warm weather conditions or during physically demanding tasks.

Moreover, the 3M H10 series is compliant with international safety standards, ensuring that it meets or exceeds the expected performance criteria for head protection. This commitment to quality provides peace of mind for both employers and employees, knowing that they are protected with some of the best technology available in the market.

In conclusion, the 3M H10 series exemplifies the intersection of safety, comfort, and versatility in head protection. With its durable materials, user-friendly design, and compatibility with accessories, the H10 stands out as a reliable choice for various industries, promoting safety without compromising comfort. As workplaces continue to prioritize employee well-being, the 3M H10 series is a vital investment in ensuring a safer working environment.