10
Command Control via the Network (continued)
Names OperationType Header CommandData
CRC Action Type SettingCode
UserGamma Pattern Set Off BE EF 03 06 00 FB FA 01 00 80 30 00 00
9step grayscale BE EF 03 06 00 6B FB 01 00 80 30 01 00
15steps grayscale BE EF 03 06 00 9B FB 01 00 8030 02 00
Ramp BE EF 03 0600 0BFA 01 00 8030 03 00
Get BEEF 03 06 00 C8 FA 02 00 8030 00 00
UserGamma Point1 Get BE EF 03 06 00 08 FE 02 00 90 30 00 00
Increment BE EF 03 06 00 6E FE 04 00 9030 00 00
Decrement BE EF 03 06 00 BF FF 05 00 90 30 00 00
UserGamma Point2 Get BE EF 03 06 00 F4 FF 02 00 91 30 00 00
Increment BE EF 03 06 00 92 FF 0400 9130 00 00
Decrement BE EF 03 06 00 43 FE 05 00 9130 00 00
UserGamma Point3 Get BE EF 03 06 00 B0 FF 02 00 92 30 00 00
Increment BE EF 03 06 00 D6 FF 04 00 9230 00 00
Decrement BE EF 03 06 00 07 FE 05 00 9230 00 00
UserGamma Point4 Get BE EF 03 06 00 4C FE 02 00 93 30 00 00
Increment BE EF 03 06 00 2A FE 04 00 9330 00 00
Decrement BE EF 03 06 00 FB FF 05 00 93 30 00 00
UserGamma Point5 Get BE EF 03 06 00 38 FF 02 00 9430 00 00
Increment BE EF 03 06 00 5E FF 0400 9430 00 00
Decrement BE EF 03 06 00 8F FE 05 00 94 30 00 00
UserGamma Point6 Get BE EF 03 06 00 C4 FE 02 00 95 30 00 00
Increment BE EF 03 06 00 A2 FE 04 00 9530 00 00
Decrement BE EF 03 06 00 73 FF 05 00 9530 00 00
UserGamma Point7 Get BE EF 03 06 00 80 FE 02 00 96 30 00 00
Increment BE EF 03 06 00 E6 FE 04 00 9630 00 00
Decrement BE EF 03 06 00 37 FF 05 00 9630 00 00
UserGamma Point8 Get BE EF 03 06 00 7C FF 02 00 97 30 00 00
Increment BE EF 03 06 00 1A FF 0400 9730 00 00
Decrement BE EF 03 06 00 CB FE 05 00 97 30 00 00
COLORTEMP Set HIGH BE EF 03 06 00 0B F5 01 00 B0 30 03 00
CUSTOM-1(HIGH) BE EF 03 06 00 CB F8 01 00 B0 30 13 00
MID BE EF 03 06 00 9B F4 0100 B0 30 02 00
CUSTOM-2(MID) BEEF 03 06 00 5B F9 0100 B030 12 00
LOW BE EF 03 06 00 6B F4 01 00 B0 30 01 00
CUSTOM-3(LOW) BE EF 03 06 00 AB F9 01 00 B030 11 00
Hi-BRIGHT-1 BE EF 03 0600 3BF2 01 00 B030 08 00
CUSTOM-4(Hi-BRIGHT-1)
BE EF 03 06 00 FB FF 01 00 B0 30 18 00
Hi-BRIGHT-2 BE EF 03 0600 AB F3 0100 B0 30 09 00
CUSTOM-5(Hi-BRIGHT-2)
BE EF 03 06 00 6B FE 01 00 B0 30 19 00
Hi-BRIGHT-3 BE EF 03 0600 5BF3 01 00 B030 0A 00
CUSTOM-6(Hi-BRIGHT-3)
BE EF 03 06 00 9B FE 01 00 B0 30 1A 00
Get BE EF 03 06 00 C8 F5 02 00 B030 00 00
COLORTEMP GAINR Get BE EF 03 0600 34F4 0200 B130 00 00
Increment BE EF 03 06 00 52 F4 0400 B130 00 00
Decrement BE EF 03 06 00 83 F5 05 00 B130 00 00
COLORTEMP GAING Get BE EF 03 0600 70 F4 0200 B230 00 00
Increment BE EF 03 06 00 16 F4 0400 B230 00 00
Decrement BE EF 03 06 00 C7 F5 05 00 B2 30 00 00