A.O. Smith AOSRG45900 warranty Residential Gas Water Heaters, Closed Combustion Power Direct-Vent

Models: AOSRG45900

1 2
Download 2 pages 3.74 Kb
Page 2
Image 2
Recovery capacity based on actual performance tests.

Residential Gas Water Heaters

Water connections, 3/4" on all models.*R Value shown is “performance rated.”11.5" MIN. CLOSED COMBUSTION

POWER DIRECT-VENT

 

FIRST

 

 

BTU

RECOVERY

 

 

 

DIMENSIONS IN INCHES

 

 

APPROX.

MODEL

HOUR

ENERGY

GAL.

INPUT

90ºF RISE

R

 

 

 

 

 

 

 

SHIPPING

NUMBER

RATING

FACTOR

CAP.

PER HOUR

GALLONS

VALUE*

A

B

C

D

E

F

BLOWER

WEIGHT

 

GALLONS

 

 

NATURAL

PER HOUR

 

 

 

 

 

 

 

OUTLET

(LBS)

GPD-40

70

.60

40

40,000

41

16

57

48-1/2

21

15

8

42

3

224

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GPD-50

87

.59

50

40,000

41

16

66

57-1/2

21

15

8

51

3

232

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GPDX-50

105

.58

50

65,000

64

16

69-1/2

61

21

15

8

54-1/2

3

232

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GPD-75

130

.58

75

70,000

72

16

71-1/2

61-1/2

26-1/4

15-1/2

8

54-3/4

3

300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GPDX-50 is supplied with 5’ of 3” ABS vent pipe and must be used for the first 5’ of the exhaust outlet vent system.

GPD-75 is supplied with 5’ of 3” CPVC vent pipe and must be used for the first 5’ of the exhaust outlet vent system.

Recovery capacity based on actual performance tests.

Water connections, 3/4" on all models.

Propane inputs/recoveries: GPD-40: 36,000BTU/37GPH GPD-50: 38,000BTU/39GPH GPDX-50: 60,000BTU/59GPH GPD-75: 65,000BTU/67GPH

*R Value shown is “performance rated.”

IMPORTANT: VENTING AND COMBUSTION AIR REQUIREMENTS

Read and follow requirements shown in the Installation Manual for ProMax® Power Direct-Vent Gas water heaters dealing with type, placement and length of vent pipe and vent termination, as well as clearances required to provide

C

3" VENTEMaximum hydrostatic working pressure: 150 psi

4"Manual backgroundManual background

adequate combustion and proper ventilation.

IMPORTANT:

SEE INSTALLATION MANUAL FOR COMBUSTION AIR AND VENTING SYSTEM REQUIREMENTS FOR POWER DIRECT-VENT WATER HEATERSManual background

OPTIONAL (DELUXE) ROUND HORIZONTAL

VENT TERMINATION KIT

Part Number 9002749

11.5" MIN.

FROM TOP OF HEATER TO CENTER LINE OF FLUE

1/2" GAS CONNECTION

3" VENT

F B A

OPTIONAL (DELUXE) SQUARE HORIZONTAL VENT TERMINATION KIT

Part Number 9003328

D

Maximum hydrostatic working pressure: 150 psi

For Technical Information and Automated Fax Service, call 800-527-1953. A.O. Smith Corporation reserves the right to make product changes or improvements without prior notice.

Created October 2008

Page 2 of 2

www.hotwater.com

AOSRG45900