TABLE OF CONTENTS
SAFE INSTALLATION, USE AND SERVICE | 2 | Vent Attenuation Assembly Installation Instructions | ||
GENERAL SAFETY | Vent Pipe Preparation | |||
TABLE OF CONTENTS | 5 | LIGHTING & OPERATING LABEL | 25 | |
INTRODUCTION | 5 | TEMPERATURE REGULATION | 26 | |
Preparing for the Installation | 5 | FOR YOUR INFORMATION | 27 | |
TYPICAL INSTALLATION | Start Up Conditions |
| ||
LOCATING THE NEW WATER HEATER | Smoke/Odor | 27 | ||
Facts to Consider About Location | Thermal Expansion | 27 | ||
Insulation Blankets | 10 | |||
Strange Sounds | 27 | |||
Combustion Air and Ventilation for Appliances |
| |||
| Operational Conditions | 27 | ||
Located in Unconfined Spaces | 10 | |||
Smelly Water | 27 | |||
Combustion Air and Ventilation for Appliances |
| |||
| “Air” in Hot Water Faucets | 27 | ||
Located in Confined Spaces | ||||
High Temperature Shut Off System | 27 | |||
INSTALLING THE WATER HEATER | ||||
PERIODIC MAINTENANCE | ||||
Chemical Vapor Corrosion | 12 | |||
Venting System Inspection | 28 | |||
Water Piping | ||||
Burner Operation and Inspection | 28 | |||
13 | ||||
Burner Cleaning | 28 | |||
Gas Piping | 14 | |||
Housekeeping | ||||
Sediment Traps | 15 | |||
Anode Rod Inspection | 29 | |||
Filling the Water Heater | 15 | |||
Vent Pipe Assembly | 15 | 29 | ||
Venting | 15 | Draining | 29 | |
Vent Pipe Termination | 16 | Service | 30 | |
Planning the Vent System | 17 | LEAKAGE CHECKPOINTS | 30 | |
Condensate | REPAIR PARTS | 31 | ||
Blower Assembly Installation | 18 | TROUBLESHOOTING | ||
Installation of Vent System | WARRANTY | 35 |
INTRODUCTION
Thank You for purchasing this water heater. Properly installed and maintained, it should give you years of trouble free service.
Abbreviations Found In This Instruction Manual:
•CSA - Canadian Standards Association
•ANSI - American National Standards Institute
•NFPA - National Fire Protection Association
•ASME - American Society of Mechanical Engineers
•GAMA - Gas Appliance Manufacturer’s Association
•UL - Underwriters Laboratories Inc.
This
PREPARING FOR THE INSTALLATION
1.Read the “General Safety” section, page 3 and 4 of this manual first and then the entire manual carefully. If you don’t follow the safety rules, the water heater will not operate properly. It could cause
DEATH, SERIOUS BODILY INJURYAND/OR PROPERTY DAMAGE.
This manual contains instructions for the installation, operation, and maintenance of the
ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER.
2.The installation must conform with these instructions and the local code authority having jurisdiction. In the absence of local codes, installations shall comply with the National Fuel Gas Code (ANSI Z223.1/NFPA 54) or the Natural Gas and Propane Installation Code (CAN/CSA B149.1) and the National Electrical Code (NFPA 70), or the Canadian Electrical Code (C22.1). These publications are available from The National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269.
3.The water heater when installed must be grounded in accordance with the local codes, or in the absence of local codes: the National Electrical Code (NFPA 70) or the Canadian Electrical Code (C22.1).
4.If after reading this manual you have any questions or do not understand any portion of the instructions, call the local gas utility or the manufacturer whose name appears on the rating plate.
5.Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires, see Figures 1 and 2.
Examine the location to ensure the water heater complies with the “Locating the New Water Heater” section in this manual.
6.For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation procedures. Instructions may be obtained from California Office of the State Architect, 400 P Street, Sacramento, CA 95814.
7.Massachusetts Code requires this water heater to be installed in accordance with Massachusetts
8.Complies with SCAQMD rule #1146 and districts having equivalent NOx requirements.
5