Commercial Gas Water Heaters
|
|
|
|
|
|
|
| Dimension Tables for BTN Models |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
| Approx. | Type of | Input |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Approx. Ship. | |||||
Model | Tank Cap. | Rating | A | B | C | D | E | F |
| G |
|
| H |
| I | J | Weight | ||||||||||||||
|
|
|
| Gas |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| (Gals.) | Btu/Hr. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Std. | ASME | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
BTN120 | 71 |
| nat | 120,000 | 63 |
| 4 1/4 |
| 59 1/2 | 50 7/8 |
| 19 5/8 |
| 19 | 1/2 |
| 51 7/8 |
| 6 |
| 27 3/4 | 400 |
| ||||||||
BTN154 | 81 |
| nat | 154,000 | 68 |
| 4 1/2 |
| 62 |
| 53 5/8 |
| 20 1/2 |
| 21 | 1/2 |
| 54 5/8 |
| 6 |
| 27 3/4 | 470 |
| |||||||
BTN180 | 99 |
| nat | 180,000 | 72 |
| 4 1/2 |
| 70 |
| 61 5/8 |
| 20 1/2 |
| 21 | 1/2 |
| 61 |
| 6 |
| 27 3/4 | 470 |
| |||||||
BTN199 | 99 |
| nat | 199,000 | 72 |
| 4 1/2 |
| 70 |
| 61 5/8 |
| 20 1/2 |
| 21 | 1/2 |
| 61 |
| 6 |
| 27 3/4 | 470 |
| |||||||
BTN200(A) | 100 |
| nat | 199,000 | 72 |
| 4 1/2 |
| 70 |
| 61 5/8 |
| 20 1/2 |
| 21 | 1/2 |
| 61 |
| 6 |
| 27 3/4 | 603 |
| 625 | ||||||
BTN250(A) | 100 |
| nat | 250,000 | 72 |
| 4 1/2 |
| 70 |
| 61 5/8 |
| 20 1/2 |
| 21 | 1/2 |
| 61 |
| 6 |
| 27 3/4 | 603 |
| 625 | ||||||
BTN275(A) | 100 |
| nat | 275,000 | 72 |
| 4 1/2 |
| 70 |
| 61 5/8 |
| 20 1/2 |
| 21 | 1/2 |
| 61 |
| 6 |
| 27 3/4 | 603 |
| 625 | ||||||
BTN310(A) | 85 |
| nat | 310,000 | 73 |
| 4 1/2 |
| 72 |
| 62 1/2 |
| 20 1/2 |
| 21 | 1/2 |
| 63 |
| 6 |
| 27 3/4 | 603 |
| 625 | ||||||
BTN366(A) | 85 |
| nat | 366,000 | 73 |
| 4 1/2 |
| 72 |
| 62 1/2 |
| 22 1/2 |
| 21 | 1/2 |
| 63 |
| 6 |
| 27 3/4 | 725 |
| 833 | ||||||
BTN400(A) | 85 |
| nat | 390,000 | 73 |
| 4 1/2 |
| 72 |
| 62 1/2 |
| 22 1/2 |
| 21 | 1/2 |
| 63 |
| 6 |
| 27 3/4 | 725 |
| 833 | ||||||
All dimensions are in inches. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| Recovery Capacities for BTN |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
| Input |
|
|
|
|
|
|
|
|
| Temperature Rise - Degrees F - Gallons Per Hour |
|
|
|
|
|
|
| ||||||||||||
Model |
| Rating |
| Gal. |
| 30 |
| 40 |
| 50 |
| 60 |
| 70 |
| 80 |
| 90 |
| 100 |
| 110 |
|
| 120 |
| 130 |
| 140 | ||
|
| Btu/Hr. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
BTN120 |
| 120,000 |
| 71 |
| 388 |
| 291 |
| 233 |
| 194 |
| 166 |
| 145 |
| 129 |
| 116 |
| 106 |
|
| 97 |
| 90 |
| 83 | ||
BTN154 |
| 154,000 |
| 81 |
| 498 |
| 373 |
| 299 |
| 249 |
| 213 |
| 187 |
| 166 |
| 149 |
| 136 |
|
| 124 |
| 115 |
| 107 | ||
BTN180 |
| 180,000 |
| 99 |
| 582 |
| 436 |
| 349 |
| 291 |
| 249 |
| 218 |
| 194 |
| 175 |
| 159 |
|
| 145 |
| 134 |
| 125 | ||
BTN199 |
| 199,000 |
| 99 |
| 643 |
| 482 |
| 386 |
| 322 |
| 276 |
| 241 |
| 214 |
| 193 |
| 175 |
|
| 161 |
| 148 |
| 138 | ||
BTN200(A) |
| 199,000 |
| 100 |
| 643 |
| 482 |
| 386 |
| 322 |
| 276 |
| 241 |
| 214 |
| 193 |
| 175 |
|
| 161 |
| 148 |
| 138 | ||
BTN250(A) |
| 250,000 |
| 100 |
| 808 |
| 606 |
| 485 |
| 404 |
| 346 |
| 303 |
| 269 |
| 242 |
| 220 |
|
| 202 |
| 186 |
| 173 | ||
BTN275(A) |
| 275,000 |
| 100 |
| 889 |
| 667 |
| 533 |
| 444 |
| 381 |
| 333 |
| 296 |
| 267 |
| 242 |
|
| 222 |
| 205 |
| 190 | ||
BTN310(A) |
| 310,000 |
| 85 |
| 1002 |
| 752 |
| 601 |
| 501 |
| 430 |
| 376 |
| 334 |
| 300 |
| 273 |
|
| 251 |
| 231 |
| 215 | ||
BTN366(A) |
| 366,000 |
| 85 |
| 1183 |
| 887 |
| 710 |
| 592 |
| 507 |
| 444 |
| 394 |
| 355 |
| 323 |
|
| 296 |
| 273 |
| 254 | ||
BTN400(A) |
| 390,000 |
| 85 |
| 1261 |
| 945 |
| 756 |
| 630 |
| 540 |
| 473 |
| 420 |
| 378 |
| 344 |
|
| 315 |
| 291 |
| 270 |
SUGGESTED SPECIFICATION
Water Heater(s) shall be Model __________ as manufactured by A. O. SMITH, or equal. Water heater(s) shall be of
and gasfired, equipped to burn __________ gas and design certified by the Underwriter Laboratory under Volume III tests for
commercial heaters for delivery of 180°F water, and meet the requirements of ASHRAE/IES
gallons. Heaters shall be equipped with 1 1/2” water inlet and outlet openings (BTN 200, 250, 275, 310 rear openings are 2”), a 2 3/4” x 3 3/4”
For Technical Information and Automated Fax Service, call
www.hotwater.com | AOSCG10500 |
Revised September 2008 | PG 4 OF 4 |