OPTIONS

OPTIONS

TANK LININGS

CEMENT – A special formulation of cement providing excel- lent corrosion protection. Available on 200 gallon and larger tanks.

EPOXY – A solventless two component epoxy lining applied to a minimum ten-mil (.010") dry thickness. Available on 200 gallon and larger tanks.

GOLDENROD ELEMENTS – Available with Optional Goldenrod Elements - All DVE/DHE models are available with the Goldenrod 24K gold plated elements (patent pending). Goldenrod Elements provide long-life and five times the scaling resistance of standard incoloy elements. Goldenrod Elements carry a three-year warranty against failure due to scale.

SPECIAL CONSTRUCTION

SILICON BRONZE VESSELS – Are available for special applications or very corrosive water conditions. Consult fac- tory for specific sizes.

STAINLESS STEEL VESSELS – Are available for deionized water. Built with stainless steel under rules of Section IV of the ASME Boiler and Pressure Vessel Code for operation on deionized water having a minimum specific resistivity of 10 megohm/cm.

150 OR 160 PSI WORKING PRESSURE – Must be speci- fied at time of order.

OTHER OPTIONAL FEATURES

TEMPERATURE AND PRESSURE RELIEF VALVES – For working pressures other than standard; consult factory.

HORIZONTAL OR VERTICAL – See specifications, most gallon capacities may be obtained in vertical or horizontal construction.

CIRCULATING PUMP PACKAGE – Circulating pump and piping sized to turn over entire storage capacity of tank once each hour. Recommended to optimize available water at temperature in horizontal tanks particularly where low draw conditions are anticipated.

OPTIONAL INTERNATIONAL VOLTAGES – 380 and 415 volts three phase.

3-1/2" DIAL TYPE PRESSURE GAUGE – Factory installed.

3-1/2" DIAL TYPE TEMPERATURE GAUGE – Factory in- stalled.

11" x 15" MANHOLE – Available as option on tanks 700 gallons or smaller.

CONTROL OPTIONS

COPPER TUBE TANK HEATER – Double wall copper tube tank heaters are designed for heating potable water with both potable or non-potable liquids or steam, and are specifically engineered for installation in models DVE and DHE for dual energy applications. Tank heaters have a positive fail-safe means of leak detection in the event of either tube failure to prevent mixture of heating medium and potable water. Single wall heat exchangers are also available. Refer to pages A 412.3 and A 412.4 for more information.

THERMOSTATIC STEP CONTROL – The simplest form of modulation. Allows elements to be stepped on in groups by specifying additional thermostats (up to one per contactor). It is recommended that number of thermostats not exceed five.

SOLID STATE MODULATING STEP CONTROL – Solid state electronic control device that modulates input to match load through progressive sequencing of steps (up to 20 steps with maximum of one per contactor).

SEQUENCER – Up to 5 stage time delay sequencer pro- vides for stepping of elements in groups or individually (maxi- mum of one step per contactor). Units supplied with this option will have a 120/24 volt control circuit.

TERMINAL BLOCKS – Allows for remote connection to build- ing demand limiter or other functions.

AUTOMATIC RESET HIGH LIMIT – A control that in the event of high temperature, interrupts power, de-energizing elements, automatic reset. (Standard with modulating step control).

INDICATING LIGHTS – Denotes heating stage(s) in opera- tion. Up to one light per contactor is available.

OVERRIDE SWITCHES – A simple means of load control allows all or part of unit input to be controlled manually. Up to one switch per contactor is available.

SAFETY DOOR INTERLOCK – Prevents opening of control panel door when heater power supply is on. NOTE: Once door is opened heater may be energized if necessary for service diagnosis.

SHUNT TRIP CIRCUIT BREAKER – A safety device (circuit breaker) which disconnects power to heater in the event of overcurrent, high temperature or low water level, breaker must be manually reset.

CIRCUIT BREAKER – A safety device which disconnects power to the heater in the event of overcurrent.

A. O. Smith Water Products Company, Inc On Line

www.hotwater.com

For Technical information and

Automated fax Service,

Phone: 800-527-1953

A. O. Smith

Water Products Company

Irving, TX

A Division of A. O. Smith Corporation

A. O. Smith Corporation reserves the right to make product changes or improvements at any time without notice.

ACESS00607

© A. O. Smith Corp., 1999

Printed in U.S.A.

Page 4 of 4

Page 4
Image 4
A.O. Smith DHE200 THRU 10, DVE125 THRU 10, 000 Other Optional Features, Control Options, ACESS00607, Tank Linings