OTHER DURA-MAX®FEATURES

Commercial Gas Boilers

OTHER DURA-MAX®FEATURES

MANUAL RESET, HIGH LIMIT ASME-RATED PRESSURE RELIEF VALVE 125#

SAFETY FLOW SWITCH REDUNDANT GAS VALVE

DURA-MAX®OPTIONS

qCSD-1

qNEW YORK CODE

qCALIFORNIA CODE

qPANEL MOUNTED INLET/OUTLET DIAL

qTHERMOMETERS AND PRESSURE GAUGE

qMOTORIZED MODULATING FIRE

qDUAL STAGE FIRING

qRIGHT HAND GAS AND/OR WATER CONNECTIONS

qCUPRO-NICKEL HEAT EXCHANGER

qSIDEWALL VENT KITSALL-BRONZE PUMP

qHIGH VELOCITY HARD WATER PUMP

qLOW WATER CUTOFF

MINIMUM CLEARANCES TO COMBUSTIBLES - ALL MODELS

 

Inches

 

CM

 

 

 

 

TOP

12

 

30.5

 

 

 

 

WATERSIDE

18

 

45.7

 

 

 

 

BLANK SIDE

6

 

15.5

 

 

 

 

REAR

6

 

15.5

 

 

 

 

VENT

6

 

15.5

 

 

 

 

FRONT

 

Alcove

 

 

 

 

INPUT AND RECOVERY

 

 

 

RECOVERY -GALLONS OR

 

BTU

GPH

LITRES PER HOUR AT

MODEL

INPUT

 

DEGREE RISE

 

OR

 

 

NUMBER

PER

 

 

 

 

LPH

40°F

100°F

 

140°F

 

HOUR*

 

 

 

 

 

 

 

22°C

56°C

 

78°C

 

 

 

 

 

 

 

DW-720

720,000

GPH

1767

707

 

505

 

 

 

 

 

LPH

6690

2676

 

1911

 

 

 

 

 

 

 

 

 

 

DW-840

840,000

GPH

2062

825

 

589

 

 

 

 

 

LPH

7805

3122

 

2230

 

 

 

 

 

 

 

 

 

 

DW-960

960,000

GPH

2356

943

 

673

 

 

 

 

 

LPH

8920

3568

 

2548

 

 

 

 

 

 

 

 

 

 

DW-1080

1,080,000

GPH

2684

1073

 

767

 

 

 

 

 

LPH

10,158

4063

 

2902

 

 

 

 

 

 

 

 

 

 

DW-1210

1,210,000

GPH

3007

1203

 

859

 

 

 

 

 

LPH

11,381

4552

 

3252

 

 

 

 

 

 

 

 

 

 

DW-1350

1,350,000

GPH

3355

1342

 

958

 

 

 

 

 

LPH

12,698

5079

 

3628

 

 

 

 

 

 

 

 

 

 

DW-1480

1,480,000

GPH

3588

1435

 

1025

 

 

 

 

 

LPH

13,581

5432

 

3880

 

 

 

 

 

 

 

 

 

 

DW-1610

1,610,000

GPH

3903

1561

 

1115

 

 

 

 

 

LPH

14,774

5910

 

4221

 

 

 

 

 

 

 

 

 

 

DW-1810

1,810,000

GPH

4388

1755

 

1254

 

 

 

 

 

LPH

16,609

6644

 

4746

 

 

 

 

 

 

 

 

 

 

* Natural gas only

Gas supply pressure: 13:8” w.c. maximum, 5.5” w.c. minimum

Electrical requirements: 120 VAC, 15 Amps