EQ / EQB

Technical specifications

 

 

EQ 115

EQ 155

EQ 200

EQ 280

EQ 380

EQB 115

EQB 155

EQB 200

Gas data natural gas 2H (G20)

 

 

 

 

 

 

 

 

 

Input*

kW

9.3

11.3

18.3

23.1

27.4

9.3

11.3

18.3

Output

kW

7.4

9.0

14.0

16.0

19.2

7.4

9.0

14.0

Inlet pressure

mbar

20

20

20

20

20

20

20

20

 

 

 

 

 

 

 

 

 

 

Burner pressure

mbar

12.5

12.5

10.5

11.5

10.0

12.5

12.5

10.5

 

 

 

 

 

 

 

 

 

 

Gas consumption**

m3/h

0.9

1.1

1.7

2.2

2.6

0.9

1.1

1.7

Diameter pilot orifice

mm

2 x 0.27

2 x 0.27

2 x 0.27

2 x 0.27

2 x 0.27

2 x 0.27

2 x 0.27

2 x 0.27

 

 

 

 

 

 

 

 

 

 

Diameter main orifice

mm

2.35

2.60

3.5

3.9

4.5

2.35

2.60

3.5

Max. flue gas temperature

°C

255

200

160

255

290

255

200

160

 

 

 

 

 

 

 

 

 

 

Gas data butane 3+ (G30)

 

 

 

 

 

 

 

 

 

Input*

kW

10.1

12.2

17.6

21.8

29.6

10.1

12.2

17.6

Output

kW

8.2

9.9

13.7

15.5

21.2

8.2

9.9

13.7

Inlet pressure

mbar

30

30

30

30

30

30

30

30

 

 

 

 

 

 

 

 

 

 

Burner pressure

mbar

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

Gas consumption**

kg/h

0.7

0.9

1.3

1.6

2.2

0.7

0.9

1.3

Diameter pilot orifice

mm

0.22

0.22

0.22

2 x 0.16

2 x 0.16

0.22

0.22

0.22

Diameter main orifice

mm

1.40

1.50

1.95

2.20

2.50

1.40

1.60

1.95

Max. flue gas temperature

°C

255

200

160

255

290

255

200

160

 

 

 

 

 

 

 

 

 

 

Gas data propane 3+ (G31)

 

 

 

 

 

 

 

 

 

Input*

kW

9.8

11.8

17.2

20.9

26.6

9.3

11.7

17.6

Output

kW

7.9

9.6

13.4

14.8

19.0

7.6

9.5

13.7

Inlet pressure

mbar

37

37

37

37

37

37

37

37

 

 

 

 

 

 

 

 

 

 

Burner pressure

mbar

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

Gas consumption**

kg/h

0.7

0.8

1.2

1.5

1.9

0.7

0.8

1.2

 

 

 

 

 

 

 

 

 

 

Diameter pilot orifice

mm

0.22

0.22

0.22

2 x 0.16

2 x 0.16

0.22

0.22

0.22

Diameter main orifice

mm

1.40

1.50

1.95

2.20

2.50

1.40

1.60

1.95

Max. flue gas temperature

°C

255

200

160

255

290

255

200

160

 

 

 

 

 

 

 

 

 

 

Draw-off capacity

 

 

 

 

 

 

 

 

 

Storage capacity

l

109

144

181

265

355

109

144

181

Max. temperature setting

°C

71

71

71

71

71

81

81

81

30 min. T=44°C

l

169

216

296

394

508

169

216

296

60 min. T=44°C

l

241

304

433

550

695

241

304

433

90 min. T=44°C

l

314

392

569

707

883

314

392

569

120 min. T=44°C

l

386

480

706

864

1070

386

480

706

 

 

 

 

 

 

 

 

 

 

Continuous T=44°C

l/h

144

175

273

313

375

144

175

273

 

 

 

 

 

 

 

 

 

 

Heating-up time T=44°C

min.

45

49

40

51

57

45

49

40

30 min. T=50°C

l

149

190

260

347

447

149

191

260

60 min. T=50°C

l

212

268

381

484

612

212

268

381

90 min. T=50°C

l

276

345

501

622

777

276

345

501

120 min. T=50°C

l

339

422

621

760

942

339

422

621

Continuous T=50°C

l/h

127

154

241

275

330

127

154

241

Heating-up time T=50°C

min.

51

56

45

58

65

51

56

45

30 min. T=55°C

l

135

173

237

315

406

135

173

237

60 min. T=55°C

l

193

243

346

440

556

193

243

346

90 min. T=55°C

l

251

313

455

565

706

251

313

455

120 min. T=55°C

l

309

384

565

691

856

309

384

565

Continuous T=55°C

l/h

116

140

219

250

300

116

140

219

Heating-up time T=55°C

min.

57

62

50

63

71

57

62

50

General

 

 

 

 

 

 

 

 

 

Anodes

-

 

 

1

 

 

 

1

 

Maximum working pressure

bar

 

 

8

 

 

 

8

 

Maximum weight

kg

156

196

256

382

499

156

196

256

Shipping data

 

 

 

 

 

 

 

 

 

Weight empty

kg

47

52

75

117

144

47

52

75

Weight incl. packaging

kg

51

57

81

135

162

51

57

81

Width packaging

mm

530

580

570

780

780

530

580

570

Height packaging

mm

1140

1250

1580

1640

1830

1140

1250

1580

Depth packaging

mm

570

630

650

870

870

570

630

650

 

 

 

 

 

 

 

 

 

 

* Gas data on gross value

** Gas consumption at 15°C and 1013.25 mbar

Page 2
Image 2
A.O. Smith EQ / EQB manual Technical specifications, Gas data natural gas 2H G20

EQ / EQB specifications

A.O. Smith is renowned for its high-quality water heating solutions, and the EQ and EQB series epitomize this dedication through their advanced technologies and user-centric features. The EQ and EQB series are designed to meet diverse residential and commercial hot water needs while prioritizing energy efficiency and performance.

One of the standout features of the A.O. Smith EQ and EQB series is their advanced energy efficiency. These water heaters are designed to minimize energy consumption, ensuring that users can enjoy hot water without excessive utility bills. The innovative insulation technology significantly reduces heat loss, enhancing overall performance and energy savings.

Another significant characteristic of the EQ series is its intuitive digital control system. This smart technology allows users to set the desired water temperature with ease, ensuring that hot water is available precisely when needed. Additionally, the digital display provides essential real-time feedback on temperature and energy usage, enhancing visibility and control over the water heating process.

The EQ and EQB models are constructed with durability in mind. Made with high-quality materials, they offer longevity and a robust performance, making them a worthwhile investment for any household or commercial establishment. The models often feature advanced anode rods designed to extend the lifespan of the tank by providing superior corrosion resistance, contributing to the overall reliability of the heater.

Safety is also a top priority in the EQ and EQB series. These models are equipped with advanced safety features, including automatic shut-off mechanisms and built-in temperature controls to prevent overheating. Users can rest assured knowing that their water heating system is safe for use in any environment.

In addition to their impressive features, the EQ and EQB series are available in various sizes and capacities to accommodate different hot water requirements. Whether for a small home or a larger establishment, A.O. Smith ensures that there is a model suited to meet the specific needs of every user.

In summary, A.O. Smith’s EQ and EQB series embody the ideal blend of efficiency, durability, and safety. With advanced digital controls, exceptional energy-saving features, and a commitment to quality, these water heaters are designed to provide reliable hot water solutions for years to come. They stand out in the market as a trusted choice for those seeking excellence in water heating technology.