A.O. Smith GW/GWO-1000, GW/GWO-2500 warranty Outdoor Models, Dim. A, Dim. B

Models: GW/GWO-1000 GW/GWO-2500

1 4
Download 4 pages 21.34 Kb
Page 3
Image 3
OUTDOOR MODELS

OUTDOOR MODELS

MODEL

DIM. "A"

DIM. "B"

GWO-1000

66.00

58.67

GWO-1300

76.50

58.67

GWO-1500

83.50

58.67

GWO-1850

97.50

61.37

GWO-2100

104.50

61.37

GWO-2500

118.50

61.37

A

31.59

18.25

B

18.07

17.39

DIRECT VENT (HORIZONTAL)

DIRECT VENT (VERTICAL)

DIRECT VENT (HORIZONTAL)

DIRECT VENT (VERTICAL)

SIDEWALL VENTING

NATURAL DRAFT

 

 

 

 

 

 

 

 

 

 

 

 

 

Natural Draft

 

 

 

 

 

 

 

 

Max. Distance W/O

 

Sidewall Venting

 

Direct Vent

 

 

 

Combustion

Barometric Damper / With

Sidewall

W/Opt. Extended Vent

 

W/Opt. Extended Vent

Model

 

Vent Size

Air Intake

Barometric Damper

Venting*

Kit (Power Assisted)

Direct Vent*

Kit (Power Assisted)

GW-1000

 

10'

8'

35’ / To Roof

70'

110'

35’ / 35'

60’ / 60'

GW-1300

 

12'

10'

35’ / To Roof

70'

110'

35’ / 35'

60’ / 60'

GW-1500

 

12'

10'

35’ / To Roof

70'

110'

35’ / 35'

60’ / 60'

GW-1850

 

14'

12'

35' / To Roof

35'

110'

15' / 15'

60' / 60'

GW-2100

 

14'

12'

35' / To Roof

35'

110'

15' / 15'

60’ / 60'

GW-2500

 

16'

14'

35' / To Roof

35'

110'

15’ / 15'

60’ / 60'

See installation manual for additional venting information further details.

 

 

 

Notes: *

Maximum three elbows

 

 

 

 

 

**Maximum two elbows -each- lntake/Exhaust

90/45 degree elbows are equivalent to 10/5 feet of vent pipe respectively.

All venting configurations terminating horizontially are Category III and require AL29-4C venting material.

All venting configurations terminating vertically are Category I and can use type B venting material (Except where local codes require AL29-4C sealed venting material.)

A 012.17

Page 3
Image 3
A.O. Smith GW/GWO-1000, GW/GWO-2500 warranty Outdoor Models, Dim. A, Dim. B