Accton Technology 1000BASE-SX Gigabit Uplink Module manual Troubleshooting, Maximum Cable Length

Models: 1000BASE-SX Gigabit Uplink Module EM4601-SX-SC E062000-R01 150471-102

1 16
Download 16 pages 24.74 Kb
Page 11
Image 11

 

 

 

 

 

 

 

 

Troubleshooting

 

Maximum Cable Length

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cable Types and Specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

Cable

Type

 

 

 

Max. Length

Connector

 

 

 

 

 

 

 

 

 

 

 

10BASE-T

Cat. 3, 4, 5 100-ohm UTP

 

100 m (328 ft)

RJ-45

 

 

 

 

 

 

 

 

 

 

 

100BASE-TX

Cat. 5 100-ohm UTP

 

100 m (328 ft)

RJ-45

 

 

 

 

 

 

 

 

 

 

100BASE-FX

50/125 or 62.5/125 micron core multimode fiber

 

 

 

 

 

 

 

 

 

 

 

 

Half duplex

 

412 m (1,351 ft.)

SC or ST

 

 

 

 

 

 

 

 

 

 

 

 

Full duplex

 

2 km (1.24 miles)

SC or ST

 

 

 

 

 

 

 

 

 

 

 

1000BASE-SX

50/125 or 62.5/125 micron core

 

See the following

SC or ST

 

 

 

multimode fiber

 

table

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Gigabit Ethernet Cable Length

 

 

 

 

 

 

 

 

 

 

 

 

 

Fiber Size

 

Fiber Bandwidth

 

Maximum Cable Length

 

 

 

 

 

 

 

 

 

 

62.5/125 micron

 

 

160 MHz/km

 

7-722 ft (2-220 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

200 MHz/km

 

7-902 ft (2-275 m)

 

 

 

 

 

 

 

 

 

 

50/125 micron

 

 

400 MHz/km

 

7-1641 ft (2-500 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

500 MHz/km

 

7-1805 ft (2-550 m)

 

 

 

 

 

 

 

 

 

 

 

Troubleshooting

If you experience any problems with the module, check the following items before contacting Accton Technical Support:

Ensure the switch with the fiber optic module is powered up.

Ensure that the device attached to the module is powered up and operating correctly.

Ensure that the module is properly seated in the slot.

Verify that the module port is configured to match the communication mode used by the attached device (full or half duplex).

Check the connectors on both ends of the cable to be sure they are properly engaged. When attaching fiber cable to an SC-type port, be sure the plug clicks into place to ensure that it is properly seated.

If you are using fiber optic cable with an ST-type connector (in conjunction with the SC-ST converter*), try switching the TX and RX connectors.

Be sure the fiber terminators are clean. You can clean the cable plugs by wiping them gently with a clean tissue or cotton ball moistened with a little ethanol. Dirty fiber terminators on fiber optic cables will impair the quality of the light transmitted through the cable.

*You may use the Cheetah ST Converter (Part Number: ST5002) to attach 62.5/ 125 micron fiber cable with an ST-type connector to the SC-type port on the fiber optic module.

5

Page 11
Image 11
Accton Technology 1000BASE-SX Gigabit Uplink Module, E062000-R01, EM4601-SX-SC manual Troubleshooting, Maximum Cable Length