Accton Technology EH2045S Hub’s RJ-45 Pin Assignments, Straight-Through, Crossover, Adapter

Models: EH2045S

1 8
Download 8 pages 912 b
Page 4
Image 4
Hub’s RJ-45 Pin Assignments

EtherHub-5st User’s Guide

Hub’s RJ-45 Pin Assignments

Pin

1

2

3

6

4,5,7,8

MDI-X Assignment

(port 1~5)

Input Receive Data +

Input Receive Data -

Output transmit Data +

Output transmit Data -

Not Used

MDI-Assignment

(Daisy-Chain Port)

Output transmit Data +

Output transmit Data -

Input Receive Data +

Input Receive Data -

Not Used

Schematics for both straight and crossover twisted-pair cable are shown below. (Note that crossover cable is only required if you cascade hubs via the RJ-45 station ports; i.e., the 5MDI Daisy-Chain port is not used.)

 

Straight-Through

 

 

 

Crossover

 

(Hub)

 

(Adapter)

(Hub)

 

 

 

(Hub)

1

IRD+

 

1

OTD+

1

IRD+

 

 

 

1 IRD+

 

 

 

2

IRD-

 

2

OTD-

2

IRD-

 

 

 

2 IRD-

 

 

 

3

OTD+

 

3

IRD+

3

OTD+

 

 

 

3 OTD+

 

 

 

 

 

6

OTD-

 

6

IRD-

6

OTD-

 

 

 

6 OTD-

 

 

 

Specifications

Transmission Technique

: Baseband

Topology

: Tree or Star

Access Method

: CSMA/CD, 10 Mbps

Standard Conformance

: IEEE 802.3 10BASE-T

Media Supported

: Category 3,4,5 twisted-pair cable

Interfaces

: 5 RJ-45 station ports, 1 RJ-45 daisy-chain port

Hub-to-Workstation Distance

: 100m max.

DimensionsDimensions

: 120mm x 96mm x 28mm (4.72" x 3.78" x 1.10")

System Power

: Requirements - 8VAC, 50/60 Hz, 5 watts

Power Adapter

: Optional external power adapter - 8 VAC, 8VA

 

for100V/120V/220-230V/240V

Temperature

: 0°C to 50°C (Standard Operating)

Humidity

: 5% to 95% (Noncondensing)

Certification

: CE Mark

Emissions

: FCC Class B, VCCI Class 2, CISPR Class B

Immunity

: IEC 801-2,3,4, EN60555-2 Class D, EN60555-3

Safety

: UL, CSA, TÜV/GS

4