Twisted-Pair Cable and Pin Assignments B

Crossover Wiring

If the twisted-pair cable is to join two ports and either both ports are labeled with an “X” (indicating MDI-X) or neither port is labeled with an “X” (which indicates MDI), a crossover must be implemented in the wiring. (When auto-negotiation is enabled for any RJ-45 port on this switch, you can use either straight-through or crossover cable to connect to any device type.)

You must connect all four wire pairs as shown in the following diagram to support Gigabit Ethernet connections.

EIA/TIA 568B RJ-45 Wiring Standard 10/100BASE-TX Crossover Cable

 

 

White/Orange Stripe

 

 

 

Orange

 

 

1

White/Green Stripe

1

End A

2

 

2

 

3

Blue

3

 

4

 

4

 

5

White/Blue Stripe

5

 

6

Green

6

 

7

7

 

8

White/Brown Stripe

8

 

 

 

End B

Brown

Figure B-3 Crossover Wiring

1000BASE-T Pin Assignments

All 1000BASE-T ports support automatic MDI/MDI-X operation, so you can use straight-through cables for all network connections to PCs or servers, or to other switches or hubs.

The table below shows the 1000BASE-T MDI and MDI-X port pinouts. These ports require that all four pairs of wires be connected. Note that for 1000BASE-T operation, all four pairs of wires are used for both transmit and receive.

Use 100-ohm Category 5, 5e or 6 unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for 1000BASE-T connections. Also be sure that the length of any twisted-pair connection does not exceed 100 meters (328 feet).

Table B-2 1000BASE-T MDI and MDI-X Port Pinouts

Pin

MDI Signal Name

MDI-X Signal Name

1

Bi-directional Data Two Plus (BI_D2+)

Bi-directional Data One Plus (BI_D1+)

 

 

 

2

Bi-directional Data Two Minus (BI_D2-)

Bi-directional Data One Minus (BI_D1-)

 

 

 

3

Bi-directional Data One Plus (BI_D1+)

Bi-directional Data Two Plus (BI_D2+)

 

 

 