Accusplit AE120XLM Other Settings, Changing Step Filter Setting, Set Step Filter set point

Models: AE120XLM

1 3
Download 3 pages 52.74 Kb
Page 3
Image 3

OTHER SETTINGS

The Step Filter setting is accessed through a special “deep set” mode.

ACCUSPLIT products use a common setting procedure known as “S1- S2-S3-S4.” Here’s how it works:

Press S1 for 2 seconds: Enter the SET mode

Press S2: Change the field to be set

Press S3: Change the field value

Press S4 for 2 seconds: Exit the SET mode

16

CHANGING STEP FILTER SETTING

While the JW200 PedometerEngine™ Step Sensor is extremely accurate, some people like to have the ability to filter out false steps. Therefore, the unit has a variable setting step filter, to allow fine-tuning to your specific preferences.You can set the value to any value from 0 – 5 steps. For example, if the filter is set to “3”, the unit will wait to start counting steps until more than three steps have been taken in less than five seconds.

Press and hold the S1 (MEMORY) button for 4 seconds.The screen will display a single digit. Press S3+ (MODE) or S3– (RESET) to change the Step Filter Setting. Press and hold S4 (Memory) for 2 seconds to exit Deep Set Mode.

Note: The unit will save any changes and exit set mode after

30 second unattended.

17

Can be set

 

 

DIGI-WALKERXL.COM

 

from 0-5

STEP

TIME

SET

 

 

 

 

steps

 

 

 

 

120XLM

JW200

S3-

S1,S2,S4

S3+

 

Set Step Filter set point

REPLACING THE BATTERY AND MASTER RESET

When the display starts to dim or goes blank, it is time to replace the battery.

If the display is not uniformly dim or blank, and appears to display “erroneous data”, do a Master Reset by pressing all 3 buttons simultaneously for 3 seconds and then release.

The display should go blank, then turn all segments on, then display 0 steps in Step Mode.

Note: All the settings will return to their default setting values. If you need to change the battery, the settings will also revert to default settings.

18

19

To replace the battery:

1.Insert a coin into the slot on the bottom of the case, and twist to loosen the faceplate. Remove

faceplate and set aside.

2. Locate the battery holder as seen

Battery

on sketch. Pull out the old battery,

 

and push a new LR-44 battery into the holder,

 

with positive terminal (+) facing up.

 

3.Snap faceplate back into place, hooking the bottom two tabs first, then closing by pressing together at the top two tabs.

20

SPECIFICATIONS, FEATURES, and FUNCTIONS Description of Functions

Counts Steps up to 99,999 then rollover.

Has aTotal Memory for Steps that counts up to 99,999,999 steps, then rollover.

CountsTime spent in step activity, up to 999 Min 59 sec, then rollover. Automatically counts whenever step activity is occurring.

Has aTotal Memory for ActivityTime that counts up to 99,999 minutes, then rollover.

Adjustable Step Filter (default setting is 1 step, but can be set from 0-5 steps) to increase step count accuracy.

21

REGISTER NOW Please return

Email (preferred)

 

 

 

your AE120XLM Registration to

User

 

the Repair Center address in the

 

 

 

 

 

warranty, and we will let you know

 

 

 

 

 

 

 

 

about future products.

 

 

 

 

NO-PROOF-OF-PURCHASE LIMITED WARRANTY

Free service for first year of ownership;

$12 fee for service thereafter. See label inside unit for date.

See www.ACCUSPLIT.com/support for details

INDEX

Battery, replacing . . . . . . . . . 19-20

Current day’s results, viewing .

. . . . 11

Memory, resetting

. . . . 15

Open your pedometer . . . .

. . . . . 4

Safety Leash . . . . . . . . . . . . 9-10

Setting up pedometer . . . .

. . . . 6-11

Step Filter Setting, change . .

. . . 16-18

TOTAL vsTRIP Memories . . .

. . . 12-13

Wearing pedometer . . . . . . . . . . 8 Warranty . . . . . . . . . . . . . . 22

22

23

Page 3
Image 3
Accusplit AE120XLM operating instructions Other Settings, Changing Step Filter Setting, Set Step Filter set point