Installing the Mylex Disk Array Controller as the Secondary UnixWare Controller with UnixWare 7.x/2.1.3
If UnixWare is installed on a Mylex controller, the Mylex Disk Array Controller driver for UnixWare is already installed in the system. Simply install the new Mylex Disk Array Controller hardware.
☛Note
If you are installing UnixWare 2.1.2 as a secondary controller, please refer to “Installing the Mylex Disk Array Controller as the Secondary UnixWare Controller with UnixWare 2.1.2” on page
If UnixWare is installed on a
☛Note
If installing onto a system that is SISL capable and using a SISL capable DAC it is recommended to disable the SCSI chip driver on the system by entering the DCU at the appropriate screen then select Software Device Drivers and disable the appropriate driver.
1.Insert the Software Kit UnixWare (dak) driver diskette into the floppy diskette drive, please refer to “Creating a Driver Diskette for UnixWare” on page
2.Type the following (match case exactly as shown): pkgadd
The new controller driver is installed.
3.Rebuild the Kernel:
/etc/conf/bin/idbuild
4.Reboot the system: shutdown