34 Chapter 1

Input Requirements
Maximum input current (A,
@90Vac, full load) 2.25A @ 90Vac
1.125A @ 180Vac
Nominal frequency (Hz) 47 - 63
Frequency variation range (Hz) 47 - 63
Nominal voltages (Vrms) 100- 240
Inrush current The maximum inrush current will be less than 50A and 100A when the adapter
is connected to 115Vac(60Hz) and 230Vac(50Hz) respectively.
Efficiency It should provide an efficiency of 83% minimum, when measured at maximum
load under 115V(60Hz).
Output Ratings
DC output voltage +18.8V~20.0V including the effects of line voltage variation, load current,
ripple and noise
Noise + Ripple 400mvp-p (20MHz bandwidth) for resistor load
Output current 0~4A
Input rated voltage 100/240V
Input current 2.25A@90Vac for Delta/ 1.125@180Vac for Lite-On
Dynamic Output Characteristics
Turn-on delay time 3 sec.
Hold up time 4 ms min. (115 Vac, input full load)
Over Voltage Protection (OVP) 29 V
Short circuit protection Output can be shorted without damage
Electrostatic discharge (ESD) 15kV (at air discharge)
8kV (at contact discharge)
Dielectric Withstand Voltage
Primary to secondary 3000Vac (4242Vdc) 10mA for 1 second
Leakage current 100uA max (240Vac, 60Hz)
Regulatory Requirements Internal filter meets;
1. FCC class B requirements.
2. VDE 243/1991 class B requirements.
3. CISPR 22 Class B requirements.
3. VCCI class II requirements.
Power Management
Power Saving Mode Phenomenon

Standby Mode

Waiting time specified by the System Standby value
or the operating system elapses without any system
activity.
Or
When the computer is about to enter Hibernation
mode (e.g. during a battery-low condition), but the
Hibernation file is invalid or not present.
The Sleep indicator lights up

Hibernation Mode

When customized functions for power management
are set to Hibernation and the corresponding action is
taken.
All power shuts off
AC Ada pte r
Item Specification