APH 8190

19” high brightness LCD Industrial panel mount monitor

2. 4 points calibration

It needs calibration before the touchscreen can work accurately. Whenever the user feel the accuracy lost, user can do calibration again to get a more accuracy touch function.

Pressing this button, a new window will be popped-up at the location when the touchscreen was mapped to area for this touch system to guide the user do 4 points calibration.

User should follows the guide to touch and hold the blinking X symbol in the calibration window until it does not blink to make sure that the utility can gather enough data for computation. In addition, a time line bar is shown in the bottom of the window to indicate time elapsed. If the touchscreen was not touched before the time line bar going to right end, the calibration task will be terminated automati- cally.

3. Clear and Calibration

Press this button to erase the 25 points calibration/linearization parameters and force user to do 4 points cali- bration again. After 25 points calibration data was clear, the 4 points calibration data will be invalid. It needs to do 4 points calibration.

4. Linearization

Linearization ( 25 or 9 points calibration ) function is used to compensate the touchscreen linearity. After lin- earization completed, the linearity of the touchscreen will be shown in the Linearity curve window.

 

© Copyright 2011 Acnodes, Inc.

661 Brea Canyon Rd., Suite 3

All rights reserved. Product description and product specifications

Walnut, CA 91789

are subject to change without notice. For latest product information,

tel: 909.598.7388, fax: 909.598.0218

please visit Acnodes’ web site at www.acnodes.com.

Page 17
Image 17
Acnodes APH 8190 user manual APH High brightness LCD Industrial panel mount monitor