INTRODUCTION

IR3200SW is a user interface of the ACTiSYS Handheld Tester ACT IR3200M for writing customer test scripts and monitoring the test. It runs under Windows.

IR3200M is a FIR/MIR/SIR Handheld Tester for testing IrDA devices. It uses standard IrDA procedures to test IrDA-compliant devices. It is not a comprehensive diagnostic or evaluation test but should be used to aid production QA tests of IrDA devices.

IR3200M has complete hardware and software built-in and can do the customer's tests stand-alone. It has a serial port RS-232 for customer test script editing, loading and test process monitoring with a desktop or notebook PC. The serial communication with PC is only receiving commands and sending result string, so that its IR speed can be as high as 4 MBPS and the cabling will not be its bottleneck.

The design of the hardware and software in the device under test (DUT) are assumed to have been fully debugged and tested to be IrDA-compliant. The goal of this program is to catch as many QA problems as possible. To catch the remaining QA problems, a more elaborate test program and disproportional amount of test time are needed. A thorough but very time consuming test is not necessarily desirable for production QA test and definitely beyond the scope of IR3200M/SW.

The main features of IR3200M/SW include its capability to discover an IrDA device in range, make connection and conduct performance tests using TEST frames. The DUT must support TEST frames, which is an suggested IrDA feature

The test process of one item will abort immediately if any error happen during discovery, make connection or test frame transfer. It will go on with the next one to avoid being stuck there for some possibly existing problem of DUT.

The Link Disconnect Time has been chosen to be 8 secs. This implies that if a link is disrupted during frame transfer. The next test can be continued after the lapse of 8 secs during which period the DUT times out and enters NDM again. However, for performance tests, the IrDA devices may be moved out of range for a max of 8 secs for the tests to continue. This feature has been included mainly for distance/angle testing.

When a DUT fails, there could be several reasons for it:

(1)Hardware Failure

(2)Software Failure.

Again, software failure could be because of IrDA-deviation or a bug in the IrDA stack. These need to be investigated carefully.

PASS does not mean that the DUT is IrDA-compliant. It means there were no preliminary QA problems. IR3200M/SW does not provide a comprehensive test of IrDA stack.

Performance test settings are based on the DUT's capabilities. For example, a DUT that supports max Frame Size of 1K, may not be tested for 2K. Likewise, a DUT that does not support FIR, may not be tested for that speed.